Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

LC202
Miniature Universal Load Cells, Stud Mount Style, 1" to 1.38" Diameter
Modèles en stock
- Miniature Package for Test Stands and Difficult Locations
- Rugged, Heavy Duty Construction
- Dual Mounting Studs for Easy Installation
- 5-Point Calibration with 59 kOhm Shunt Cal Data
LC202
Depuis
C$
1,293.60
Modèles en stock

L'aperçu du produit
- 5-Point Calibration 0%, 50%, 100%, 50%, 0%
- Calibration Option 5 POINT NIST
- Electrical Connection Cable
- Enclosure Ratings IP65
- Force Type Compression, Tension
- Input Resistance 360 Ω min
- Load Cell Type In-line
- Materials Stainless Steel
- Operating Temperature, Max 121 °C
- Operating Temperature, Min -54 °C
- Output Resistance 350 ± 10 Ω
- Overload, Max 300% FS
- Process Temperature, Max 71 °C
- Process Temperature, Min 16 °C
- Safe Overload 150% FS
- Supply Power Note 10 Vdc, 15 Vdc maximum
- Thermal Span Effect 0.009% FSO/°C
- Thermal Zero Effect 0.009% FSO/°C
- Wiring/Connector Table Green: (+) Output; White: (-) Output; Black: (-) Input; Red: (+) Input
- Zero/Balance Error ± 2%
OMEGA’s LC202 Series Load Cell offers the designer a compact series with ranges from 50 lb to 10,000 lb and accuracy of 0.25%. The all stainless steel construction and rugged design assure long life in industrial and commercial applications.
The LC202 is also available in metric configurations, with ranges from 0-100 to 0-50,000 N and metric threads. Please see the LCM202 for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc, 15 Vdc max
Output: 2 mV/V nominal
Accuracy: ± 0.25% FSO (linearity, hysteresis, repeatability combined)
5-Point Calibration: 0%, 50%, 100%, 50%, 0%
Zero Balance: ± 2% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.009% FSO/°C
Span: 0.009% FSO/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Input Resistance: 360 ? minimum
Output Resistance: 350 ± 10 ?
Construction: Stainless steel
Electrical: 1.5 m (5') 4-conductor cable
Protection Class: IP65
The LC202 is also available in metric configurations, with ranges from 0-100 to 0-50,000 N and metric threads. Please see the LCM202 for complete details, or contact our Pressure department for more information.
SPECIFICATIONS
Excitation: 10 Vdc, 15 Vdc max
Output: 2 mV/V nominal
Accuracy: ± 0.25% FSO (linearity, hysteresis, repeatability combined)
5-Point Calibration: 0%, 50%, 100%, 50%, 0%
Zero Balance: ± 2% FSO
Operating Temp Range: -54 to 121°C (-65 to 250°F)
Compensated Temp Range: 16 to 71°C (60 to 160°F)
Thermal Effects:
Zero: 0.009% FSO/°C
Span: 0.009% FSO/°C
Safe Overload: 150% of capacity
Ultimate Overload: 300% of capacity
Input Resistance: 360 ? minimum
Output Resistance: 350 ± 10 ?
Construction: Stainless steel
Electrical: 1.5 m (5') 4-conductor cable
Protection Class: IP65
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
justinraade from
reliable data
The unit is functioning well and producing good data on tension. I'm happy with the purchase.
Date published: 2016-11-14
Rated 5 out of
5
by
KimH from
Cable
Cable works as expected. Pricing was good. Delivery was timely.
Date published: 2024-01-23
Rated 3 out of
5
by
James P from
The Omega 2000 lbf load cell is too tiny.
We never used the Omega 2000 lbf load cell. It looked too small to hold-up to 2000 lbf with the gorillas that work on our system. We went with a more robust larger load cell instead that could stand more unintentional abuse. The typical load is ~ 700 lbf, however, someone could overload it by accident. If the load cell failed and the load dropped, I would never hear the end of it.
Date published: 2023-08-14
Rated 5 out of
5
by
Sidd from
Easy Setup
It was easily set up with the DPS20-LV and initial testing seems to have went well.
Date published: 2023-03-06
Hello there, What is the maximum load rate the LC202-2k load cell can accurately measure? Is this load cell suitable for dynamic loading conditions/impulse such as 0N-8000N-4600N (2000lb model) in a matter of 15-30ms? Thank you!
Thank you for your inquire.
These load cells do not handle dynamic applications. They may work for a short period but they will fail after time and we do not recommend this type of usage.
Hope this was helpful.
Date published: 2022-01-25
How do you compensated for temperature, and how much accuracy would I lose at -40deg F?
We use Wheatstone bridge for temp compensation. The CTR for this load cell is 16 to 71°C (60 to 160°F) with Accuracy: ±0.25% FSO linearity,
hysteresis, repeatability combined for this temp range. If you are out of this range at (-40°F) you will be out of the accuracy of ±0.25% FSO.
Date published: 2024-10-25
Does the LC202-10K load cell read in 1 pound increments or in fractions of a pound?
Anthony, the load cell will put out a linear mV across the range no matter what the load is. Assuming that the load cell puts out 0 to 30 mV across the range, a one pound load will result in a load cell output of 0.003 mV. Most data acquisition modules will not be able to adequately capture that low of a mV reading.
So, the resolution and how low of a load you are able to read will really depend on your data acquisition system.
Date published: 2023-09-07
What size conductors are in the cable?
Thank you for your inquiry, the conductor size is 28 AWG
Date published: 2022-05-19
Can this load cell be used in dynamic (high frequency) loading conditions? 0-peak 1500N at 400Hz?
Thanks for your inquiry
LCM202 Is not a good low cell to be used in a dynamic loading conditions .Please Contact us directly with more information about your application and we can make some recommendations for load cell that may be better suited for those conditions.
Date published: 2020-07-20
What is the weight of this load cell? And what is the full output scale?
Aysha, weight of the unit will be 0.440 pounds and the full span output will be 20 mV if you use 10 volts DC excitation over the span you choose.
Date published: 2020-04-28
How much of a side load or moment load can these sensors handle?
There is no published data indicating maximum side loading or moment. Side loading should be kept to a minimum.
Date published: 2022-03-22
What is the sensitivity of this load cell (50kN)
The output is an analog signal. Nominal sensitivity is 2.0 mV/V meaning that if a 10VDC excitation power is supplied to the cell you will getting a linear 0 to 20 mVDC
output signal over the 0 to 50kN range. This working out to about a 0.4 mV change per kN. The NIST traceable calibration report supplied with the load cell would indicate your exact mV/V sensitivity.
Date published: 2019-12-21