Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

OS-TX-USB-Series
Modbus IR Transmitter with 4-20 mA and USB outputs
- IR Transmitter with MODBUS over USB for use with other software or devices
- PC configuration, real-time display, charting and CSV text file logging via free software
- Features Max, Min, Average and Instantaneous Readings Peak or Valley Hold Reflected Energy Compensation
- Stainless Steel Housing, Sealed to IP65
OS-TX-USB-Series
Depuis
C$
901.10

L'aperçu du produit
- Cable Length 1 m
- Data Interface USB
- Data Interface Note USB 2.0 (removable USB cable and software included) using the Modbus protocol
- Display No
- Emissivity, Max 1
- Emissivity, Min 0.1
- Enclosure Ratings IP65
- Housing Material Stainless Steel
- Impedance 900 Ω
- Intrisically Safe No
- Laser Output false
- Operating Temperature, Max 70 °C
- Operating Temperature, Min 0 °C
- Relative Humidity Note 95% max. non-condensing
- Repeatability ± 0.5°C
- Repeatability Note ± 0.5°C or 0.5% of readi ng, whichever is greater
- Response Time 200 ms
- Sensing head Mounting 20 mm
- Sensor Voltage 6 Vdc
- Span, Max Full temperture Range
- Span, Min 100 °C
- Supply Voltage 24 to 28 Vdc
- USB Cable Length 1.8 m
- Weight 155 g
The OS-TX-USB-series infrared temperature transmitters can accurately and consistently measure temperatures from -40 to 2000ºC (-40 to 3632ºF) and have an excellent response time of 200 ms. The sensor will operate with 4 to 20 mA, 2-wire output (loop-powered), the USB cable, or both. When using only USB output, no external power is required.
The free OmegaConfig software is a simple application that can be configured via the included USB cable, displayed in real time, graphed and recorded in CSV text files. User-configurable settings include 4 to 20 mA output scale, emissivity, average, peak / valley, and reflected energy compensation. MODBUS over USB communication also allows measurement data to be configured and read through other compatible applications or user-written software.
The USB cable has an IP65 connector on the sensor side. The IP65 cap protects the sensor when the USB cable is not connected.
PDF et manuels
Logiciels et pilotes
Afficher les notes et les avis
Rated 5 out of
5
by
Gary W from
Perfect for what it was purchased for.
Does exactly what we needed it to, will purchase again.
Date published: 2024-11-05
Can this unit be calibrated?
It does not appear to have been calibrated in the past but send a follow up to temp@dwyeromega.com and it can be reviewed.
Date published: 2024-06-07