Modèles en stock
- RS485 Modbus Communications
- Optional touch-screen display for configuration, alarms and datalogging
- Create a standalone, 6-channel modbus system
- Build larger systems using the TSD600’s separate modbus
OS-MINIHUB
Depuis
C$
437.06
Modèles en stock

L'aperçu du produit
- Additional Features 1 Touch Screen Display
- Applications Automotive, Building and Maintenance, Energy Generation and Distribution, Food and Beverage, Fuel and Gas, Heat and Energy Systems, Industrial and Manufacturing, Materials and Surfaces, Packaging and Printing
- Baud Rate 9600
- Baud Rate Note Other configurations available upon request
- Cable Length 1 m
- Cable Length Note 1 m (3.3') (longer lengths available to order)
- Calibration UKAS traceable calibration certificate, add (-CALA)suffix to each sensor to be calibrated
- Configuration Via TSD600 touch screen, or directly via RS485 Modbus
- Configuration Parameters Averaging, Emissivity Setting, Peak/Valley Hold Processing, Reflected Energy Compensation
- Data Interface RS485 Modbus
- Data Interface Note RS485 Modbus RTU
- Display NO
- Emissivity, Max 1
- Emissivity, Min 0.2
- Enclosure Ratings IP65
- Intrisically Safe No
- Laser Output false
- Operating Temperature, Max 120 °C
- Operating Temperature, Min 0 °C
- Optional Power 100 to 240 Vac
- Optional Power Note 100 to 240 Vac, 0.3 A
- Relative Humidity, Max 0.95
- Relative Humidity Note 95% max non-condensing
- Repeatability Note ± 0.5% of reading or ± 0.5ºC
- Sensing head Mounting 16 mm
- Spectral Response, Min 8 μm
- Supply Current 50 mA
- Supply Voltage 6 to 28 Vdc
- Weight 85 g
- Weight Note 85 g (3 oz), without cable
The OS-MINIHUB is an industrial infrared temperature monitoring system, with miniature sensing heads and optional display modules. OS-MINIHUB sensors are designed to measure the surface temperature of non-reflective materials in industrial applications, from -20 to 1000°C (-4 to 1832°F). They are sealed to NEMA 4 (IP65), built from 316 stainless steel, and fully tested to industrial EMC standards.
They can measure food, paper, thick plastics, asphalt, paint, bulk materials and organic materials, as well as most dirty, rusty or oily surfaces.
RobustOS-MINIHUB sensors have an operating temperature rating of up to 120°C (248°F) with no need for cooling.
CompactThe sensors measure just 45 mm (1.7"") long (plus cable gland), so they can fit into the smallest of spaces.
ConfigurableUp to 6 sensors can be connected to the optional TSD600 interface module, which provides temperature display, configuration, and high-capacity data logging to a MicroSD Card. Analog and relay outputs are available via separate DIN rail mounted modules.
Low CostWith up to 6 sensors connected to one TSD600, the OS-MINIHUB is an ideal low-cost non-contact temperature measurement system.
NetworkableTo measure more than 6 locations, OS-MiniHUB sensors and TSD600 sub-networks may be connected to an RS485 Modbus SCADA system or PLC. It is possible to measure the temperature of hundreds or thousands of locations on the same network.
ApplicationsThe OS-MINIHUB may be installed as a new temperature monitoring system, or integrated into an existing Modbus network. With two Modbus interfaces, the TSD600 makes an ideal local display for a group of sensors as part of a larger system. The OS-MINIHUB-JB6 junction box makes it easy to connect the system together. Never miss a critical temperature event. In condition monitoring applications, the OS-MiniHUB system is an always-on solution that can replace manual checks with a handheld thermometer or expensive thermal imager.
Typical ApplicationsCuring Ovens Fiberglass impregnated with epoxy is cured in an oven to increase strength. OS-MiniHUB sensors are placed inside the oven at up to 120°C (248°F), to build-up a temperature profile at many points on the entire surface of the workpiece, and to communicate the measured temperature to the heating system that controls the hot air blowers in the oven. Industries include boatbuilding and aerospace as well as many others.
Industrial BakeriesCheck the temperature profile of bakery products at multiple points along a conveyor oven.
Corrugated Board ManufacturingMonitor the web temperature along an entire corrugator, with local displays for each section of the production line, and centralized monitoring in the control room. Sensors withstand 120°C (248°F), and can be used in hightemperature areas such as single facers without cooling.
Power DistributionMonitor the temperature of bulbar joints in switchgear cabinets. Hundreds or even thousands of points can be monitored on the same network using the OS-MiniHUB system.
AutomotiveA large system of OS-MiniHUB sensors can monitor the paint curing process at several points. Monitor temperatures around the entire vehicle in environmental test chambers.
Condition MonitoringA network of OS-MiniHUB sensors can monitor all the bearing temperatures on a machine, a runout table, or the whole factory. The OS-MiniHUB is ideal for measuring the temperature of all painted metal surfaces.
Infrared CuringArrays of sensors fitted on a rig of infrared curing lamps ensure an even temperature profile along the part being cured. Surface coatings, paint and epoxy are ideal target materials, among many others.
Gas Cylinder FillingMonitor temperatures to improve repeatability in the filled volume and improve filling efficiency. The temperature of every cylinder on a filling rig is easily monitored with no need to manually move contact probes.
PDF et manuels
Afficher les notes et les avis
Can the sensor wire length be longer? Can I splice a wire to it and make it twenty or thirty feet?
Hello Tim
Yes the wire length can be extended if needed.
Date published: 2020-05-16
What kind of cable does this communicate from?
Hi tREY,
Thank you for the inquiry. Terminations accept 18 to 28 awg conductors. You'll need 4 conductors for use with the RS485 communication signal. TX4-100 is an example; 4 conductor 100 ft spool.
Best regards
OMEGA