FMA6703

Multi Parameter Mass Flowmeter

Choisissez une variante

Burst Pressure
Volumetric Flow Rate, Max

C$3 341.55

Article# FMA6703

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Accuracy ± 1 %
Accuracy Note 0°C to 50°C and 5 to 100 psia (34.5 - 689.5 kPa): ± 1% of full scale (F.S.)
Additional Features 1 2 SPDT 1A Relay, Multi-parameter Display
Altitude Sensitivity Incremental deviation of up to 1% from stated accuracy, after re-zeroing
Burst Pressure 200 psi Maximum
Calibration NIST 10-Point Certificate
Circuit Protection Reverse polarity, Current Limit, Resettable Fuse
Compliance CE
Data Interface RS485
Data Interface Note The digital interface operates via RS485 (optional RS232 is available)
Display Note 128 x 64 graphic LCD with backlight (up to 8 lines of text). User selectable backlight saver.
Display Type LCD
Electrical Output 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc
Enclosure Ratings Inst. Level II/Poll. Degree II (IEC 60664)
Humidity Range Up to 70%
Leak Rate Under Vacuum less than 10^⁻9 cc He/s
Materials, Wetted 316 Stainless Steel, 416 Stainless Steel, FKM
Media Compatibility Air, Gases, Nitrogen, Oxygen
Operating Pressure, Max 100 psi
Operating Pressure, Min 0 psi
Operating Temperature, Max 50 °C
Operating Temperature, Min -10 °C
Output Detail Linear 0-5 Vdc (3000 ohms min load impedance); Linear 0-10Vdc (6000 ohms min impedance); Linear 4-20 mA (500 ohms maximum loop resistance). Maximum noise 20mV peak to peak (for 0-5 Vdc output).
Output Signal Current, Voltage
Pressure Accuracy ± 1 %
Pressure Coefficient 0.01% FS/psi
Pressure Drop, Max 0.04 psi
Process Connection Size 1/4 in
Process Connection Type Compression Fitting
Process Temperature, Max 50 °C
Process Temperature, Min 0 °C
Repeatability ± 0.15%
Response Time 300 ms
Response Time Note 300ms time constant; approximately 1 second to within ± 2% of set flow rate for 25% to 100% of full scale flow.
Supply Power Note May be configured for three different options: Bipolar ± 15Vdc (± 200 mA maximum); Unipolar +12Vdc (300 mA maximum); Unipolar +24Vdc (250 mA maximum); Circuit boards have built-in polarity reversal protection. Resettable fuses provide power input protection
Supply Voltage Bipolar ± 15Vdc, Unipolar 12Vdc to 24Vdc
Temperature Accuracy ± 1 °C
Temperature Coefficient 0.15% FS/°C
Volumetric Flow Rate, Max 50 SCCM
Volumetric Flow Rate, Min 0.2 SCCM
Weight 2.2 lb