Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

AM-2250

Multi-Variable Controller - pH, ORP, Contacting Conductivity, Flow

Choisissez une variante

Supply Voltage
Electrical Output
Relay Output

C$1,649.13

Article# AM-2250

En stock

Délai de livraison (si pas en stock): 6 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Additional Features 1 PID Control, Sensors Sold Separately
Calibration Note pH Calibration modes: Automatic or Manual 2 or 3 points; ORP Calibration modes: Manual 1 point; Conductivity Calibration modes: Up to 16 points; Flow Calibration modes: K factor input
Compliance ETL
Compliance Note ETL (US and Canada) and CE pending
Conductivity Measurement 0.055 to 500,000 µS/cm
Cutout Dimensions 5.4 x 5.4 in
Display Type LCD
Electrical Output 4 to 20 mA
Enclosure Ratings NEMA Type 4X
Flow Indication Note 0 to 999 in any units
Height 5.5 in
Input Range Note pH Sensor Input: -600 to +600 mV; ORP Sensor Input: -999 to +999 mV; Conductivity Sensor Input: 0 to 9999 Ω; Flow Sensor Input: 0 to 2000 Hz
Length 5 in
Mounting Orientation Panel Mount, Wall Mount
Number of Relays 3
ORP Measurement Range -1000 to +1000 mV
Operating Humidity 0 to 90% RH
Operating Temperature, Max 120 °C
Operating Temperature, Min -20 °C
Output Detail Two 4-20 mA outputs, Scalable 4-20mA with PID (Process), Scalable 4-20mA (Process or Temperature), Optically isolated. Max Load - 800 Ω
PH Measurement Range 0 to 14.00 pH
Power Consumption 0.2 A @ 115 Vac or 15 W
Process Temperature, Max -20 °C
Process Temperature, Min 70 °C
Relay Note 3 Dry contact relay with snubber circuit, 10A @ 120/240 VAC or 8A @ 30 VDC (Resistive Load), 5A @ 120/240 VAC or 4A @30 VDC (Inductive load) Relay Modes: Rising/Falling/In Range. Options: Relay Delay, Cycle, Overfeed Timer, Override, One relay can be triggered by temperature or flow totalizer.
Relay Output Dry contact relay
Sensing Element 100/1000 Ω RTD, 300/3K Ω NTC or none
Sensing Element Note PH, ORP, Conductivity: 100, 1000 Ω, RTD 300, 3K Ω NTC or none
Sensor Type Note pH Sensor: 6-Wire Differential or Combination; ORP Sensor: 6-Wire Differential or Combination; Conductivity Sensor: 4-Wire contacting : Any cell constant between 0.01 and 100; Flow Sensor: Pulse output: Paddle-wheel, Magmete
Supply Voltage 120/240 Vac
Temperature Compensation Automatic: pH ;Automatic or Manual: Conductivity ;Display temperature: ORP ;Display Flow Totalizer: Flow
Temperature Measurement Note pH, ORP, Conductivity : -20 to 120 °C, Flow : Flow Totalizer 0 to 999 in any units
Weight 2 lb
Width 5.5 in
Voir toutes Spécs Montrer moins
Multi-Variable Controller - pH, ORP, Contacting Conductivity, Flow AM-2250 AM-2250