Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

FMG90B-Series
OEM Lightweight and Compact Design Electromagnetic Flow Meter
Modèles en stock
- Magnetic Flow Meter with No Moving Parts or Obstructions
- Independent to Changes of Temperature, Pressure, Viscosity
- Lightweight and Compact Design
- PVDF and 316L Wetted Parts
- Fast Response (<100 ms)
- See Accessories for Cables and Power Supplies
FMG90B-Series
Depuis
C$
1,430.27
Modèles en stock

L'aperçu du produit
- Accuracy ± 0.7 %
- Accuracy Note ± 0.7 % of reading ± 0.3 % of range
- Cable Length 10 m
- Conductivity > 20 µS/cm
- Electrical Connection M12 4 pin Female
- Enclosure Ratings IP65
- Flow Indication LED Green
- Flow Indication Note LED Green, Flow proportional flashing
- Media Compatibility Acid Solutions, Conductive Liquids, Saltwater
- Number of Outputs 1
- Operating Pressure, Max 145 psi
- Operating Temperature, Max 140 °F
- Operating Temperature, Min 41 °F
- Output Detail 0.5 to 10 V
- Power Consumption max 3.6 W
- Process Temperature, Max 140 °F
- Process Temperature, Min 14 °F
- Repeatability ± 1%
- Response Time < 100 ms
- Storage Temperature, Max 140 °F
- Storage Temperature, Min 5 °F
- Supply Power Note 12 to 24 Vdc(± 10 %)
- Supply Power Type DC
- Supply Voltage 12 to 24 Vdc
- Weight 0 lb
OMEGA’s FMG90B Series electro-magnetic flow sensor for conductive liquid media was developed for OEM applications and does not contain any moving parts. FMG90B series is the most economic electromagnetic flowmeter due to the cost optimized plastic construction. Its design is compact and lightweight. Six flow ranges are available. Changes in temperature, density, viscosity, concentration or electrical conductivity of the medium do not affect the output signal. The sensor is intended for continuous measurement of flow rates or for dosing/batching of liquids with a minimum conductivity of 20 ?S/cm. .
PDF et manuels
Afficher les notes et les avis
Will work with pulps that have 20% of solids??
Thank you for your inquiry about this magnetic flow meter. Magnetic flow meters can be used with fluids that have suspended particles in stream since there are no moving parts and the liquid must be conductive that has at least 20 microSiemens dielectric.
Date published: 2022-09-07
It is suitable for HFO outlet purifier? what is working principle of this type
Thank you for your inquiry about the magnetic flow meter. If this liquid, HFO, is conductive or has a dielectric constant greater than 20 microSiemens, than, it will be suitable since it works based on Faraday's Principle in measuring flow.
Date published: 2022-03-17