Local Monitoring and Connectivity with Omega Enterprise Gateway
The new Omega Enterprise Gateway software (OEG 2.0) makes monitoring and control simpler and more intelligent by providing 24/7 surveillance into your processes with seamless connectivity to Layer N cloud services. Easily integrate your Omega devices into your infrastructure with OPC-UA/DA.
Download and get optimal insight into your process
OEG Essential | OEG Pro | OEG Business | OEG Business Pro | |
FREE | $395 Lifetime License | $695 Lifetime License | $995 Lifetime License | |
For individuals, academics, or startups with simple applications and a few sensors | For larger installations with a growing number of sensors that can benefit from analytics for greater decision making | For businesses deploying Industrial Automation using OPC UA/DA | For large organizations with multiple locations that need different user level access. Includes 3rd party device support. | |
Download | Purchase | Purchase | Purchase | |
Device Management Add, Delete, Search, and Configure devices | ☑ | ☑ | ☑ | ☑ |
Real-Time Sensor Data Display displays live readings for your device | ☑ | ☑ | ☑ | ☑ |
Historic Data for Individual Sensor Allows user to change from live readings to a specified range of time | ☑ | ☑ | ☑ | ☑ |
Alarm Settings Create software adjustable alarms for each of your devices | ☑ | ☑ | ☑ | ☑ |
E-mail and SMS Notifications Received Alarm and Event notifications via E-mail or SMS | ☑ | ☑ | ☑ | ☑ |
Alarms & Events Hisory View past alarm or even messages describing the nature of each in detail. | x | ☑ | ☑ | ☑ |
Device Insight Analytics on the health and activity of your ecosystem | ☑ | ☑ | ☑ | ☑ |
Does Not Require Internet Connection No internet connection is required to operate. | ☑ | ☑ | ☑ | ☑ |
Intranet Access Access your data from any device connected to your intranet network | ☑ | ☑ | ☑ | ☑ |
Cloud support (Free and Premium Subscription) Access your data anywhere using the Layer N Cloud | x | ☑ | ☑ | ☑ |
Dashboard / Monitoring Page Fully customizable to monitor your live device data | x | ☑ | ☑ | ☑ |
Value Scaling/Calibration Scaling and offset calibration support | x | ☑ | ☑ | ☑ |
Historian and Prediction Displays past readings of device(s) and predict future values | x | ☑ | ☑ | ☑ |
Map Allows access to map pages | x | ☑ | ☑ | ☑ |
OPC UA/DA Server allows compliant enterprise application to retrieve sensing data | x | x | ☑ | ☑ |
Multi-Level Access Allows account to have more than one user. | x | x | x | ☑ |
Third Party Devices 3rd Party Device integration through MODBUS or ASCII | x | x | x | ☑ |
Afficher les notes et les avis
Rated 5 out of
5
by
jtramel from
Great Product Offering!!
While working with some Omega sensors, I wanted to integrate it in with our HMI system, and was hoping for something with the up to date OPC-UA standard. Didn't see anything, so I dropped an email, and was allowed to be a part of Beta testing for this new software. After a couple rounds of troubleshooting with feedback and some updates of the software, I am happy to say it is up and working very well. Nice software and great support
Date published: 2017-09-11
How will I be informed of software upgrades? Are the upgrades free?
You will receive an email from Omega prompting you to download the newest version of OEG every 2-3 months with bug fixes, additional functionality, and updated features. Our OEG web page will contain the most up-to-date software package for download and it’s free to upgrade to same license.
Date published: 2018-02-25
Is the Omega Enterprise Gateway compatible with OM-USB-2404(4-Channel Analog Voltage Input USB Data Acquisition Modules)?
Thanks for contacting Omega. Unfortunately, OEG is not compatible with OM-USB-2404. This question has been sent to our management team so we can add this compatibility in the future.
Date published: 2019-01-15
Can I download OEG on multiple devices with one license?
If you download OEG onto a main server, any computer on the network can access the data via a web search engine. If OEG is placed on a PC, only that PC will be able to access OEG.
Date published: 2018-06-12
Can the software be configured with user controls and audit trails so that it could be 21CFRPart11 compliant for the pharmaceutical industry?
Hello, thank you for reaching out to us. The OEG is not compliant with the title 21 CFR Part 11 regulation. Unfortunately, OEG does not support electronic signatures at this time.
Date published: 2019-01-15
How do I add/remove devices in OEG?
If you select the “devices” tab on the top right-hand side of the OEG home screen, you’ll be taken to a screen to add/remove devices. Please contact our Tech Support if you need further assistance.
Date published: 2018-01-10
How do our devices integrate with a PLC?
Omega devices can connect to the PLC via its Ethernet (TCP/IP) port. OEG is installed on a PC and the data from the Omega sensing device is transferred into OEGs database; OEG is always recording data even if PLC is unstable or disconnected. Using the OPC UA/DA protocol, the PLC may then act as a client and request the data from OEG, the virtual server. Additional lines of code are unnecessary with the OPC UA/DA enabled feature of OEG.
Date published: 2019-01-15
What computer system do I need to run OEG? And what are the hardware requirements?
Omega Enterprise Gateway can run on:
Windows 7, 8, and 10 (64-bit or 32-bit), Windows Server 2008, 2012, and 2016, CPU Dual Core > 2.4GHz, Memory > 4GB, and Hard Drive > 250GB.
Date published: 2017-12-13
Can I send control demands from OEG to controllers?
OEG is only setup to display and record your process information and is incapable of sending commands to your process. For process control, consider one of our controllers that can send control outputs as well as provide the data to OEG. View one of our controller series here https://www.omega.com/pptst/CNPT_SERIES.html
Date published: 2019-01-15