SP-014-Series
Omega Link M12 Modular Smart Probe Analog Process interface with I/O
Modèles en stock
- Up to 3x Current Loop (0-24mA) or
- Up to 3x mV (0-1.0 VDC)
- 2x Digital I/O
- Software configurable through SYNC configuration software
SP-014-Series
Depuis
C$
226.47
Modèles en stock

L'aperçu du produit
- Approvals CE, UKCA
- Configuration Configurable via Omega Link Smart Interface and SYNC configuration software
- Digital Input VinHighThreshold = 2.2 VMAX, VinLowThreshold = 0.3 VMIN, VinMAX = 30 VDC
- Digital Output 2x Open Drain 100 mA max, VMAX = 30 VDC
- Enclosure Ratings IP67
- Input Control Signal Current Loop: 4 to 20 mA, Voltage: 0 to 1.0 Vdc, 0 to 2.0 Vdc
- Input Note ON: 1.0 Vdc, OFF: 0.7 Vdc, Internal Pull Up/Down: 1.5k to 3.0 Vdc, Comparator (Pulse) Input: 100 mV, 500 mV, 1.0 Vdc, 2.0 Vdc
- Length 96.7 mm
- Number of Channels 3
- Number of I/O 2
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Software Compatible with OEG, SYNC, and OMEGA Cloud
- Supply Power Type DC
- Supply Voltage 2.8 to 3.3 Vdc
- Width 22.1 mm
The Omega Link SP-014 Process Monitoring Smart Probe provides an easy way to integrate process signals to your Omega Link Ecosystem. The SP-014 accepts standard process signals through its M12 5-pin connector and Omega Link Smart Interfaces through its M12 8-pin connector. The optional M12.5-S- M-FM connector can be utilized to easily connect wire leads to your SP-014.
Each of the 3 process inputs may be independently configured as 0-24 mA or 0-1.0 VDC inputs.
Intuitive Configuration
Configure your Omega Link Smart Probe using SYNC’s intuitive configuration interface.
Edge Control and Built in I/O
The Omega Link SP-014 features 2 configurable digital I/O pins. These can be used for a myriad of applications including driving relays, physical alarms, or sensing dry contacts like door switches. The SP-014 can also be utilized as an edge controller, with autonomous independent decision-making capabilities to generate local alarms or provide control outputs based on sensor inputs.
Smart Core Enabled
Smart core is integral to all Omega Link Smart Probes. This powerful suite of advanced features enable plug and play connectivity, alarms and notifications, data assurance, data logging, and storage.
Smart Interface Modularity
Customize your Omega Link Ecosystem with modular Smart Interfaces that connect and transmit data from your Smart Probe to the Omega Link Cloud.

Your Data at a Glance with Omega Link Cloud
Omega Link Cloud consolidates and brings your data to you when you need it, wherever you are. The intuitive cloud interface allows you to monitor and store your data, set alarms and alerts, and provides insights on device activity. Visit the OMEGA website for more details.


Specifications
INPUT POWER
Voltage: 2.8 VDC - 3.3 VDCDIO DIGITAL INPUTS
VinHighThreshold= 2.2 VMAXVinLowThreshold= 0.3 VMIN
VinMAX= 30 VDC
DIO DIGITAL OUTPUTS
2x Open Drain 100 mA maxVMAX= 30 VDC
ENVIRONMENTAL
Operating Temperature: -40 to 85℃ (-40 to 185℉)Rating: IP67 when mated
MECHANICAL
Dimensions: 22.1 mm W x 96.7 mm L (0.87” x 3.80”) not including mounting tabsGENERAL
Agency Approvals: CE, EMC 2014/30/EU, LVD 2014/35/EUCompatibility: Compatible with OEG, SYNC configuration software, Omega Link Cloud, and Modbus Networks
M12 5-Pin Wiring

Pin | mA | mV |
---|---|---|
Pin 1 | 3.3V Power | |
Pin 2 | Input 0 | Input 0 |
Pin 3 | GND | |
Pin 4 | Input 1 | Input 1 |
Pin 5 | Input 2 | Input 2 |
M12 8-Pin Wiring

Pin | Name | Function |
---|---|---|
Pin 1 | DIO 0 | Discrete I/O Signal 0 |
Pin 2 | INTR | Interrupt Signal |
Pin 3 | SCL | I2C Clock Signal |
Pin 4 | SDA | I2C Data Signal |
Pin 5 | Shield | Shield Ground |
Pin 6 | DIO 1 | Discrete I/O Signal 1 |
Pin 7 | GND | Power Ground |
Pin 8 | 3.3VDD | Power Supply |
Omega Link SP-014
Model Number | Description |
---|---|
SP-014-1 | Process Monitoring Smart Probe with discrete I/O |
Omega Link Smart Interface
Omega Link Smart Probes require an Omega Link Smart Interface to operate and connect to your Omega Link Ecosystem
Model Number | Description |
---|---|
IF-001 | USB Smart Interface |
IF-002 | RS485/Modbus Smart Interface |
Accessories
An optional M12 5-pin screw terminal adapter is available for users who wish to connect wire leads directly to the SP-014.
Model Number | Description |
---|---|
M12.5-S-M-FM | M12 5-pin screw terminal adapter |
M12.8-T-SPLIT | Smart Probe M12-8 pin shielded T-Splitter - enables access to I/O pins |
M12.8-S-M-FM | M12-8 pin Straight Plug Field install connector with screw terminals |
DM12CAB-8-1-RA | 1m (3.3’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-3-RA | 3m (9.8’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-5-RA | 5m (16.4’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-1 | 1m (3.3’) cable dual M12-8 straight connector |
DM12CAB-8-3 | 3m (9.8’) cable dual M12-8 straight connector |
DM12CAB-8-5 | 5m (16.4’) cable dual M12-8 straight connector |
PDF et manuels
Logiciels et pilotes
Afficher les notes et les avis