Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

SP-010-Series
Omega Link M12 Modular Smart Probe Load Cell interface with I/O
Modèles en stock
- Autoscaling 350 ohm - 5000 ohm Bridge Input Circuits
- Auto adjusted activation current
- Hardware and software TARE function
- 2-point Linearization
SP-010-Series
Depuis
C$
205.05
Modèles en stock

L'aperçu du produit
- Accuracy ± 0.03 %
- Accuracy Note Linearity Error: ±0.03% FSO @ 25°C, Thermal Error: ±0.005% FSO/C
- Approvals CE, UKCA
- Configuration Configurable via Omega Link Smart Interface and SYNC configuration software
- Digital Input VinHighThreshold = 2.2 VMAX, VinLowThreshold = 0.3 VMIN, VinMAX = 30 VDC
- Digital Output 2x Open Drain 100 mA max, VMAX = 30 VDC
- Enclosure Ratings IP67
- Length 96.7 mm
- Number of Channels 1
- Number of I/O 2
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -40 °C
- Reading Rate 1 sample per second max
- Software Compatible with OEG, SYNC, and OMEGA Cloud
- Supply Power Type DC
- Supply Voltage 2.8 to 3.3 Vdc
- Width 22.1 mm
The Omega Link SP-010 Load Cell Smart Probe provides an easy way to integrate your bridge devices to the Omega Link Ecosystem. The SP-010 accepts 4-wire bridge sensors through its M12 4-pin connector and Omega Link Smart Interfaces through its M12 8-pin connector. The M12-S-M-FM accessory connector can be utilized to easily connect wire leads to your SP-010.
The SP-010 determines the bridge impedance and applies an optimized pulsed bridge excitation current during measurements to minimize self-heating effects. The bridge voltage is then used to determine the applied force using bridge characteristics provided by the user.
A 2-point linearization correction may be applied with the ability to capture the measured values. TARE weight adjustment can be triggered through software or external switch closures.
Intuitive Configuration
Configure your Omega Link Smart Probe using SYNC’s intuitive configuration interface. Additionally, an integrated command line interface allows for quick serial setup of your Smart Probe and Smart Interface using standard terminal emulators.
Edge Control and Built in I/O
The Omega Link SP-010 features 2 configurable digital I/O pins. These can be used for a myriad of applications including driving relays, physical alarms, or sensing dry contacts like door switches. The SP-010 can also be utilized as an edge controller, with autonomous independent decision-making capabilities to generate local alarms or provide control outputs based on sensor inputs.
Smart Core Enabled
Smart Core is integral to all Omega Link Smart Probes. This powerful suite of advanced features enable plug and play connectivity, alarms and notifications, data assurance, data logging, and storage.
Smart Interface Modularity
Customize your Omega Link Ecosystem with modular Smart Interfaces that connect and transmit data from your Smart Probe to the Omega Link Cloud.

Your Data at a Glance with Omega Link Cloud
Omega Link Cloud consolidates and brings your data to you when you need it, wherever you are. The intuitive cloud interface allows you to monitor and store your data, set alarms and alerts, and provides insights on device activity. Visit the OMEGA website for more details.


Specifications
INPUT POWER
Voltage: 2.8 VDC - 3.3 VDCDIO DIGITAL INPUTS
VinHighThreshold= 2.2 VMAXVinLowThreshold= 0.3 VMIN
VinMAX= 30 VDC
DIO DIGITAL INPUTS
2x Open Drain 100 mA maxVMAX= 30 VDC
MEASUREMENTS
Supported Strain GaugesBridge Sensitivity: 1 to 15 mV/V
Bridge Resistance: 250 to 15000 Ohm
Accuracy
Linearity Error: ± 0.03% FSO
Thermal Error: ± 0.005% FSO/C
ENVIRONMENTAL
Operating Temperature: -40 to 85℃ (-40 to 185℉)Rating: IP67 when mated
MECHANICAL
Dimensions: 22.1 mm W x 96.7 mm L (0.87” x 3.80”) not including mounting tabsGENERAL
Agency Approvals: CE, EMC 2014/30/EU, LVD 2014/35/EUCompatibility: Compatible with OEG, SYNC configuration software, Omega Link Cloud, and Modbus Networks
M12 4-Pin Wiring

Pin | Name | Function |
---|---|---|
Pin 1 | Exc - | Excitation return |
Pin 2 | Sense + | Bridge Output |
Pin 3 | Sense - | Bridge Output |
Pin 4 | Exc + | Bridge Excitation |
M12 8-Pin Wiring

Pin | Name | Function |
---|---|---|
Pin 1 | DIO 0 | Discrete I/O Signal 0 |
Pin 2 | INTR | Interrupt Signal |
Pin 3 | SCL | I2C Clock Signal |
Pin 4 | SDA | I2C Data Signal |
Pin 5 | Shield | Shield Ground |
Pin 6 | DIO 1 | Discrete I/O Signal 1 |
Pin 7 | GND | Power Ground |
Pin 8 | 3.3VDD | Power Supply |
Omega Link SP-010
Model Number | Description |
---|---|
SP-010-1 | Load Cell Smart Probe with discrete I/O |
Omega Link Smart Interface
Omega Link Smart Probes require an Omega Link Smart Interface to operate and connect to your Omega Link Ecosystem. There are both wired and wireless options.
Model Number | Description |
---|---|
IF-001 | USB Smart Interface |
IF-002 | RS485/Modbus Smart Interface |
Accessories
An optional M12 4-pin screw terminal adapter is available for users who wish to connect wire leads directly to the SP-010-1.
Model Number | Description |
---|---|
LCKD | Subminiature Load Cell with Rugged Industrial Design |
M12-S-M-FM | M12 4-pin screw terminal adapter |
M12.8-T-SPLIT | Smart Probe M12-8 pin shielded T-Splitter - enables access to I/O pins |
M12.8-S-M-FM | M12-8 pin Straight Plug Field install connector with screw terminals |
DM12CAB-8-1-RA | 1m (3.3’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-3-RA | 3m (9.8’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-5-RA | 5m (16.4’) cable dual M12-8 connector, right angle terminator |
DM12CAB-8-1 | 1m (3.3’) cable dual M12-8 straight connector |
DM12CAB-8-3 | 3m (9.8’) cable dual M12-8 straight connector |
DM12CAB-8-5 | 5m (16.4’) cable dual M12-8 straight connector |

PDF et manuels
Logiciels et pilotes
Afficher les notes et les avis