Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

CT5100

1 or 2 Channel, 10" Circular Chart Recorders

C$2,979.31

Article# CT5100

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$2,979.31
5-9 C$2,830.34
10-24 C$2,770.76
25-49 C$2,651.59
50-99 C$2,592.00
100+ C$2,532.41

En stock

Délai de livraison (si pas en stock): 16 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Accuracy ± 0.5 %
Accuracy Note Chart Recording: 0.5% of chart span reference accuracy, Chart Rotation: ±0.5% of rotation time, assuming all backlash removed, Chart Rotation: ±0.5%, Chart Speed: ±1%
Approvals UL, FM
Approvals Note Safety: UL Approved for USA:UL 1092, UL 916 and QUXY, pending UL Certified for Canada:CSA Spec 142, pending Limit/Device: FM, pending
CMRR >120 dB @ 50/60 Hz, 260 Vac max
Chart Diameter 254 mm
Chart Note Chart Span: Bottom and top of span, -9999 to 9999 units; Chart Drive: DC Stepper Motor; Chart Drive: Stepper Motor
Chart Speed 8 Hours to 7 Days
Cold Junction Compensation 0.04°/°C deviation from 25°C
Conduit Entrance 3 Openings on the Right Side
Current Measurement Range 0 to 20 mA
Cutout Dimensions 322.58 x 322.58 mm
Data protection EEPROM Storage
Display Note 4-digit, 14 mm H (0.56"), red, 7-segment, LED display, Display Modes: Normal: process value(s) or blank Keypad: 3 keys for programming and unit operation
Display Type LED
Enclosure Ratings IP54, NEMA Type 3
Height 355.6 mm
Impedance Input >100 MΩ for T/C and mV inputs, 100 kΩ for 5 V inputs, 4.7 Ω for µA inputs
Input Note Input Correction: Offset adjustment: 999 to 999 units;Input Isolation: 350 Vac, 500 Vdc
LED Indicators 5 Red LED Alarm Status Indicators, 1 green LED pen 2 indicator
Length 96.5 mm
Material Construction Option Standard
Materials Noryl, Acrylic
Measurement Range Note Thermocouple: J: 0 to 760°C, K: 0 to 1360°C, T: -200 to 400°C, R: 200 to 1650°C, S: 200 to 1650°C RTD: -140 to 400°C Current: 0 to 20 mA, 4 to 20 mA Voltage: 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
Measurement Type Thermocouple, RTD, Current, Voltage
Mounting Panel Mount or Wall Mounting
NMRR 85 db @ 60 Hz or greater
Number of Channels 1
Number of Relays N/A
Operating Environment Reference Operating Condition: 25 °C
Operating Temperature, Max 50 °C
Operating Temperature, Min 0 °C
Panel Depth 64 mm
Panel Protrusion 33 mm
Pen Type Disposable Fiber tip
Power Consumption 18 VA
RTD Type 100 Ω Pt sensor; α= 0.00385
Recording Color Pen 1: Red
Relative Humidity 10 to 90% RH, non-condensing
Sampling Rate 1 Scan per second for Non-RTD inputs; 1 Scan per 1.2 seconds for RTD inputs
Sensor Break Detection Sensor Fault Detection: Display goes to “SnSr” and pen goes up-scale if a sensor break is detected. No sensor break can be detected for zero-based volt and milliamp ranges. Display goes to “Hi” 10% above span; display goes to “Lo” 10% below span or zero, whichever is higher.
Sensor Input Configuration 150 µA
Standard Limits of Error Error Limit: Cold-Junction Compensation Error: ±0.2°C @ 25°C, Linearization Error: T/Cs: ±0.25°C typical, ±0.5°C worst case , RTDs: ±0.1°C typical, ±0.3°C worst case, Ambient Temperature Error: ±0.01% of span per °C deviation from 25°C; Measurement Error: Type J, K, T, R, S and RTD: ±0.25% of span ±1 degree; mA, mV and Vdc: ±0.25% of scaled span plus 1 leastsignificant digit
Storage Temperature, Max 65 °C
Storage Temperature, Min -40 °C
Supply Power Note Line Voltage: 90/264 Vac, 50/60 Hz; optional: 20 to 50 Vac, 50/60 Hz, or 22 to 65 Vdc
Supply Power Type AC
Supply Voltage 90 to 264 Vac
Switch Rating 5 A @ 115 Vac
Switch Rating Note Relays: SPDT; contacts rated 5 A resistive @ 115 Vac,2.5 A resistive @ 230 Vac, 1⁄8 hp @ 230 Vac (single phase),250 VA @ 115/230 Vac
Switch Type SPDT NO/NC, Selectable
Temperature Measurement Range J: 0 to 760°C, K: 0 to 1360°C, T: -200 to 400°C, R: 200 to 1650°C, S: 200 to 1650°C, RTD: -140 to 400°C
Thermocouple Type J, K, T, R, S
Voltage Measurement Range 0 to 25 mV, 0 to 50 mV, 10 to 50 mV, 0 to 5 V, 1 to 5 V
Weight 8.8 kg
Width 355.6 mm
Wire Code Option 2- or 3- Wire
Voir toutes Spécs Montrer moins
1 or 2 Channel, 10" Circular Chart Recorders CT5100 CT5100
Rated 4 out of 5 by from USER FRIENDLY WE HAVE HAD THESE FOR A FEW YEARS . TWELVE OF THEM THROUGH OUT THE PLANT THEY HAVE WARE AND TEAR, SO WE NEED A PART BREAK DOWN AND SERVICE MANUEL .I AM TOLD THEY IS NONE. WHY?
Date published: 2017-07-31
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_CT5100, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration