CT9000-Series
Microprocesser-Based Circular Chart Recorders, 1 to 4 Pen, 10 to 12" Charts, T/C, RTD, V, mV, mA or Switch Input, Up to 4 Alarms per Variable,
- 1-, 2-, 3- or 4-Pen Version
- Programmable for 254, 280, 305 mm (10, 11 or 12') Charts
- Accepts Thermocouple, RTD, V, mV, mA or Switch Signals
- 40 Character Display
CT9000-Series
Depuis
C$
7,027.61

L'aperçu du produit
- Accuracy ± 1 °C (± 1.8 °F)
- Accuracy Note Thermocouple: 1°C, Chart Accuracy: 0.3%, Chart Rotation: 0.2 minutes for 24 hours
- Alarm Note Alarm Type: Process high or low, rate rising or falling, Alarm Number: Up to 4 alarms for each of 4 process variables
- Approvals CE
- Battery life up to 10 yr
- Battery Size and Type Li-ion
- Chart Diameter 305 mm
- Chart Note Chart Messages: 12; Chart Drive: DC Stepper Motor
- Chart Speed 6 to 9999 Hours
- CMRR >120 dB
- Cold Junction Compensation 0.04°/°C deviation from 25°C
- Current Measurement Range 4 to 20 mA
- Cutout Dimensions 322.58 x 322.58 mm
- Deadband Fully adjustable
- Display Note 2-line, 40-character VFD with 5 mm (0.21") high characters, Display Formats: 3, Operator Messages: 12, Operator Inputs: 12 Keypad: 15 keys for programming and unit operation
- Display Type VFD
- Enclosure Ratings IP54, NEMA Type 3
- Height 425.96 mm
- Input Note Input Isolation: 350 Vac, 500 Vdc;Contact Closure: Open/closed switch sensing without external voltages or resistors;Value Cutoff: None, at Value, to Zero below value, to Zero near Zero
- LED Indicators 8 User Configurable, Red LED Status Indicator
- Length 196.85 mm
- Measurement Range Note Thermocouple: J: -200 to 1200°C, K: -250 to 1370°C, E: -250 to 1000°C, N: -250 to 1300°C, T: -250 to 400°C, R: 200 to 1700°C, S: 250 to 1750°C, B: 200 to 1800°C, G: 0 to 2300°C, C: 0 to 2300°C, D: 0 to 2300°C, NNM: 0 to 1370°C, PLATINEL II: 0 to 1400°C RTD: -200 to 480°C Current: 0 to 20 mA, 4 to 20 mA Voltage: 0 to 25 mV, 0 to 100 mV, 0 to 1V, 0 to 10V
- Measurement Type Thermocouple, RTD, Current, Voltage, Switch Signals
- Mounting Panel Mount or Wall Mounting
- Mounting Orientation ± 30 degrees forward/backward of vertical, ± 10 degrees side tilt from vertical
- NMRR 100 dB @ 60 Hz
- Number of Channels 1
- Operating Temperature, Max 50 °C
- Operating Temperature, Min 0 °C
- Panel Depth 133.35 mm
- Panel Protrusion 63.5 mm
- Pen Type Fiber tip Marker Assembly
- Power Consumption 60 VA
- Programmable Functions Exponential Function, Square Root Function
- Recording Note Recorded Values: 20 values can be trended/recorded, Recording Methods: Drag pen simulation, instantaneous value, connect the values, average value, connect the averages\
- Relative Humidity 10 to 90% RH, non-condensing
- RTD Type 100 Ω Pt sensor; α= 0.00385
- Sampling Rate 2 Scans/sec
- Sensor Break Detection Sensor Fault Detection: Sensor break on all T/Cs, RTDs, 1V, 1 to 5V, 4 to 20 mA and mV ranges; sensors high and low on all inputs, 5% above or below range; Sensor Break: Up-scale or down-scale
- Standard Limits of Error Error Limit: Measurement Error: ±0.025% of measurement span reference accuracy, Cold-Junction Compensation Error: ±0.2°C @ 25°C, Linearization Error: T±0.25°C typical, ±0.5°C worst case with exceptions; RTD: ±0.1°C typical, ±0.3°C worst case, Ambient Temperature Error: ±0.01% of span per °C; Measurement Error: ±0.025% of measurement span reference accuracy
- Storage Temperature, Max 65 °C
- Storage Temperature, Min -40 °C
- Supply Power Note 90 to 264 Vac, 50/60 Hz
- Supply Power Type AC
- Supply Voltage 90 to 264 Vac
- Temperature Measurement Range J: -130 to 760°C, K: -130 to 1370°C, T: -200 to 400°C, R: 0 to 1650°C, S: 0 to1649°C, B: 100 to 1824°C, RTD: -210 to 440°C
- Thermocouple Type J, K, T, R, S, N, E, B, C, G, D
- Time Accuracy 1 min/month Typically, 4 min/month worst case
- Vibration 0.3 to 100 Hz @ 0.2 g
- Voltage Measurement Range 0 to 5 Vdc
- Weight 11.34 kg
- Width 358.65 mm
- Wire Code Option 2- or 3- Wire
The CT9000 microprocessor-based circular recorder offers one to four trends with one color per channel. The latter allows future trend addition upgrades and improves chart annotation of times, dates, scale values, trend line tags, and user configurable real time actuated chart messages. The instrument can have up to eight inputs. Some inputs do not have to be associated with the trend pens, i.e. display only. Up to four process values can be displayed on the 40-character vacuum fluorescent display at one time (2 lines of 20 characters each). Full English prompts allow easy configuration of the unit. Using proven dotting head print technology, there is no time difference on the chart between trend lines. This feature, along with the straight radial time line (compared to the curved lines on other recorders) allows for more accurate reading of data. The unit uses plain paper charts with pre-printed rings to further enhance readability and provide better long-term storage.