Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

FTB8000HW-Series
Hot Water Flow Meters for Totalization and Rate Indication
Modèles en stock
- Flow Rates from 0.22 to 132 GPM
- 150 psi Maximum Operating Pressure
- 90°C (194°F) Maximum Operating Temperature
- Field-Adjustable Pulse Output (Optional)
FTB8000HW-Series
Depuis
C$
381.03
Modèles en stock

L'aperçu du produit
- Accuracy ± 1.5 %
- Approvals RoHS
- Cable Length 12 ft
- Display Mechanical Counter
- Materials, Wetted Alnico, Bronze, Thermoplastic
- Media Compatibility Liquids
- Operating Pressure, Max 150 psi
- Operating Temperature, Max 150 °C
- Process Connection Type NPT Male
- Supply Voltage 24 Vdc
The FTB8000HW Series meters use the multi-jet principle, which has been an internationally accepted standard for many years. This type of meter is known for its wide range, simplicity, and accuracy in lowquality water. The impeller is centered in a ring of jets, with inlet jets on one level and outlet jets on another. A gear train drives the register totalizer dials. For pulse output, one of the dials is replaced by a gear, which turns a magnet that is detected by an encapsulated sensor threaded into the outside of the lens. Pulse rate is determined by the gear and the dial on which the gear is placed. Changing the pulse rate requires no special tools and can be done in the field.
Mechanically, all FTB8000HW meters are the same. The difference between the -PR, -PT, and standard models is in the sensor. -PR model meters use a solid state, longlasting Hall-effect sensor, which requires power. -PT model meters use a 2-wire reed switch. They provide a dry-contact closure and do not require power. Basic FTB8000HW meters totalize only and do not have an output. Never install water meters above or over areas where leakage would cause damage.
SPECIFICATIONS
Materials:
Body: Cast bronze
Internals: Engineered thermoplastic
Magnet: Permanent ceramic
Max Temperature: 90°C (194°F)
Max Operating Pressure: 150 psi
Accuracy: 1.5% of reading
Sensor:
-PR: Hall-effect device
-PT: Reed switch
Max Current: 20 mA
Max Voltage:
-PR: 24 Vdc
-PT: 24 Vdc or Vac
Sensor Power (-PR): Minimum 6 mA at 12 Vdc
Cable Length: 4 m (12') standard, 600 m (2000') max
Flow Rates (GPM):
Mechanically, all FTB8000HW meters are the same. The difference between the -PR, -PT, and standard models is in the sensor. -PR model meters use a solid state, longlasting Hall-effect sensor, which requires power. -PT model meters use a 2-wire reed switch. They provide a dry-contact closure and do not require power. Basic FTB8000HW meters totalize only and do not have an output. Never install water meters above or over areas where leakage would cause damage.
SPECIFICATIONS
Materials:
Body: Cast bronze
Internals: Engineered thermoplastic
Magnet: Permanent ceramic
Max Temperature: 90°C (194°F)
Max Operating Pressure: 150 psi
Accuracy: 1.5% of reading
Sensor:
-PR: Hall-effect device
-PT: Reed switch
Max Current: 20 mA
Max Voltage:
-PR: 24 Vdc
-PT: 24 Vdc or Vac
Sensor Power (-PR): Minimum 6 mA at 12 Vdc
Cable Length: 4 m (12') standard, 600 m (2000') max
Flow Rates (GPM):
NPT Size | ¾ | 1 | 1½ | 2 |
---|---|---|---|---|
Minimum | 0.22 | 0.44 | 0.88 | 1.98 |
Maximum | 22 | 52 | 88 | 132 |
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
Glass Engineering from
Water Meters
Reliable for application we need it for. Usually available w/ short lead times.
Date published: 2023-07-12
does the ftb8010hw meet lead free drinking water requirements
Thank you for your inquiry. Unfortunately, it is not rated for potable water applications nor is it lead free.
Date published: 2024-09-24
Can this device output flow rate?
Thank you for your inquiry. Yes, and the suffix of the part number would end in '-PR' for pulse rate.
Date published: 2021-01-12
With this installed in a horizontal position, can the register face down instead of up?
Thank you for your inquiry! Unfortunately, installation with the register facing down is not recommended. The register should be facing up when mounted horizontally for accurate results.
Date published: 2022-02-01
For Model FTB8010HW Omega Pulse meter, is the part 32238 internal assemby available? If so what is cost and lead time?
Thank you for your inquiry about the pulse meter. Please compose an email and forward to the Customer Care Group at cservice@omega.com and they will advise on the price and lead time for that spare part.
Date published: 2021-12-14
Is this meter serviceable? I have one that needs a new turbine and gauge face, is there anyway to reach out and potentially purchase rebuild/replacement parts?
Thank you for your inquiry! Unfortunately, we do not offer individual replacement components for this series of flow meter
Date published: 2021-08-17
How do I request a longer cable in the part number? I need 50 ft.
Thank you for your inquiry! A 50 foot cable is non standard and therefore we do not have a method to indicate the cable length in the part number. Please send us an email at flow@omega.com so that we can discuss this this application
Date published: 2021-08-05
Can you get just the reed switch for these water meters?
Thank you for your inquiry. Yes, you can adjust the pulse rate for the reed switch.
Date published: 2020-06-18