Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

LDI-619
LVIT Linear Position Sensors
Modèles en stock
- Excellent stroke-to-length ratio
- Rugged 19 mm (0.75') Diameter stainless steel housing
- Field adjustable range scaling
- Wide Choice of Range: 15 to 750 mm (⅝” to 30') Full Scale
LDI-619
Depuis
C$
310.61
Modèles en stock

L'aperçu du produit
- Additional Features 1 Non-Contact LVIT
- Bandwidth 300 Hz (-3 dB)
- Cable Type Insulated
- Enclosure Ratings IP67
- Housing Material Stainless Steel
- Operating Temperature, Max 85 °C
- Operating Temperature, Min -20 °C
- Relative Humidity 95% RH, non-condensing
- Resolution 0.025% of FS
- Shock 1000 g, 11 ms
- Temperature Coefficient 0.015% of FS/°C
- Vibration 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
The LDI-619 Series LVIT (Linear Variable Inductive Transducer) position sensors from OmegaTM are devices designed for factory automation and a variety of industrial and commercial applications such as motor sport vehicles, automotive testing, solar cell positioners, wind turbine prop pitch and brakes, and packing equipment. With their compact device, rugged stainless-steel construction, superior performance, and excellent stroke-to-length ratio, the LDI-619 sensors are ideal for both industrial testing, laboratories, and OEM applications.
LDI-619 sensors are offered in 15 full scale ranges from 15 to 900 mm (â… to 36"). Calibration and set-up is simplified with one wire field programming feature, this provides the ability to match the end points of the sensor's analog output with the ends of the range of motion of the assembly to which the sensor is attached. This feature permits a user to optimize the position measuring system's resolution over its full range of motion.
LDI-619 products come with axil exiting cable & a M5 x 0.8 threaded end for installation.
Specifications
Analog I/Os:
0 to 10V output with 12 to 30V input, 35 mA max;
4 to 20 mA (3-wire) output with 18 to 30V input, 60 mA max 75°C (167°F max)
Measuring Range: 2.5 to 900 mm (â…” to 36") Full Scale
Linearity Error: ±0.15% of Full Scale Output (FSO) typical, ±0.25% max
Resolution: 0.025% of FS
Update Rate: 300 Hz nominal
Operating Temperature: -20 to 85°C (-4 to 185°F)
Temperature Coefficient: 0.015% of FS/°C
Vibration: 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Shock: 1000 g, 11 ms
Terminations: IEC IP67
Humidity: 95% RH, non-condensing
Housing Material: Stainless steel
LDI-619 sensors are offered in 15 full scale ranges from 15 to 900 mm (â… to 36"). Calibration and set-up is simplified with one wire field programming feature, this provides the ability to match the end points of the sensor's analog output with the ends of the range of motion of the assembly to which the sensor is attached. This feature permits a user to optimize the position measuring system's resolution over its full range of motion.
LDI-619 products come with axil exiting cable & a M5 x 0.8 threaded end for installation.
Specifications
Analog I/Os:
0 to 10V output with 12 to 30V input, 35 mA max;
4 to 20 mA (3-wire) output with 18 to 30V input, 60 mA max 75°C (167°F max)
Measuring Range: 2.5 to 900 mm (â…” to 36") Full Scale
Linearity Error: ±0.15% of Full Scale Output (FSO) typical, ±0.25% max
Resolution: 0.025% of FS
Update Rate: 300 Hz nominal
Operating Temperature: -20 to 85°C (-4 to 185°F)
Temperature Coefficient: 0.015% of FS/°C
Vibration: 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Shock: 1000 g, 11 ms
Terminations: IEC IP67
Humidity: 95% RH, non-condensing
Housing Material: Stainless steel
Wiring Table | |
---|---|
I/O Function | Color |
+Power Input | Red |
Ground | Black |
Analog output | Green |
Field Programming | White |
Shield/ drain* | Shield |
*Shield unconnected internally |

LDI-619 Range Table | ||
---|---|---|
Nominal Range | Length “A” | |
Inches | mm | mm (Inches) |
≤1 | ≤25 | 35.0 (1.38) |
1.2 | 30 | 41.3 (1.63) |
2 | 50 | 60.5 (2.38) |
3 | 75 | 85.9 (3.38) |
4 | 100 | 111.1 (4.38) |
6 | 150 | 165.1 (6.5) |
8 | 200 | 215.9 (8.50) |
10 | 250 | 266.7 (10.50) |
12 | 300 | 317.5 (12.50) |
15 | 375 | 400.0 (15.75) |
18 | 450 | 476.2 (18.75) |
24 | 600 | 635.0 (25.00) |
30 | 750 | 787.4 (31.00) |
Afficher les notes et les avis
Rated 5 out of
5
by
Anonymous from
LVDT (0-50 mm)
I received the product on time and it works perfectly fine. I have ordered three of these till now and never had issues.
Date published: 2022-10-26
Hi. Do you have a recommended power supply for this item?
Thank you for your inquiry
One power supply that would be a good match is the PSS-D12A
This will supply the power needed for these units.
Hope this was helpful
Date published: 2020-04-22
Hi, could you please tell me how long the threaded end (M5x0.8) for installation is? Unfortunately there is nothing mentioned about this length in the spec sheet or manual. Please advise. Thanks, Manuela
Length of the M5x0.8 threaded area at end of the shaft is 9.7mm (0.38"0
Date published: 2020-02-13
Hi are you able to apply pressure to retract this product to zero position? (spring load, compressed air, etc) I only see one photo so I don't know if this possible.Thank you
Thank you for your inquiry, this unit isn’t spring loaded or pneumatic. Please see our model GP911-1-P
Date published: 2023-01-17
Do these sensors come with signal conditioners? If not, which signal conditioners do you offer are most compatible with these sensors?
No signal conditioning is required with these sensor. The output is already conditioned to either a 4 to 20 mADC or 0 to 10VDC signal
Date published: 2021-02-09
The "stud" came with insulation over the majority of its length. Is that to be left on or removed?
Thank you for your inquiry, yes, the insulation can be removed
Date published: 2022-07-14