- High Precalibrated Accuracy: ± 0.5°C (0.9°F) Maximum @ 25°C
- Excellent Linearity: 0.15°C (0.27°F) Maximum [0 to 70°C (32 to 158°F)]
- Wide Operating Temperature Range: -25 to 105°C (-13 to 221°F)
- Single Supply Operation: +4 to +30V
OM-2628
Depuis
C$
187.55
Modèles en stock

L'aperçu du produit
- Accuracy Note Calibration Error @ 25°C (77°F) 0.3°C (0.54°F) typical, 0.5°C (0.9°F) maximum TA = 0 to 70°C (32 to 158°F): Error Over Temperature: 0.4°C (0.72°F) typical, 0.8°C (1.4°F) maximum Nonlinearity: 0.05°C (0.09°F) typical, 0.15°C (0.27°F) maximum TA = -25 to 105°C (-13 to 221°F): Error Over Temperature: 0.5°C (0.9°F) typical, 1°C (1.8°F) maximum Nonlinearity: 0.1°C (0.18°F) typical, 0.35°C (0.63°F) maximum
- Forward Voltage ± 44 V
- Insulation PFA
- Linearity 0.15°C
- Linearity Note Excellent Linearity: 0.15°C (0.27°F) Maximum [0 to 70°C (32 to 158°F)]
- Long Term Stability 0.1°C/month
- Long Term Stability Note 0.1°C/month (0.18°F) typical
- Nominal Current Output 298.2 µA
- Nominal Current Output Note Nominal Current Output @ 25°C (298.2 K): 298.2 µA typical
- Package Temperature, Max 125 °C
- Package Temperature, Min -45 °C
- Probe Diameter 0.25 in
- Probe Type Integrated Circuit Temperature Probes
- Process Temperature, Max 105 °C
- Process Temperature, Min -25 °C
- Repeatability 0.1°C
- Repeatability Note 0.1°C (0.18°F) typical
- Reverse Voltage ± 20 V
- Reverse Voltage Note Reverse Voltage (- to +) Lead Temperature: 20V maximum
- Soldering 572 °C
- Soldering Note Soldering, 10 Seconds: 572°C (1062°F) maximum
- Temperature Coefficient 1 µA/°C
- Temperature Coefficient Note 1 µA/°C typical
- Temperature Probe Style Immersion Probe
- Temperature Sensor Type Thermistor
The OM-2628 IC probe features the integrated circuit transducer AD592CN. This IC solid state sensor is a two terminal monolithic integrated circuit temperature transducer that provides an output current proportional to absolute temperature. For a wide range of supply voltages the transducer acts as a high impedance temperature dependent current source of 1 µA/K. Improved design and laser wafer trimming of the IC’s thin film resistors allows the AD592CN solid state sensor to achieve absolute accuracy levels and nonlinearity errors previously unattainable at a comparable price.
The OM-2628 probe can be employed in applications between -25 and 105°C (-13 to 221°F) where conventional temperature sensors (i.e., thermistor, RTD, thermocouple, diode) are currently being used. Expensive linearization circuitry, precision voltage references, bridge components, resistance measuring circuitry and cold junction compensation are not required with the OM-2628 probe.
The OM-2628 solid state sensor is particularly useful in remote sensing applications, the AD592CN is immune to voltage drops and voltage noise over long lines due to its high impedance current output.
Specifications
Accuracy
Calibration Error @ 25°C (77°F) TA = 0 to 70°C (32 to 158°F): 0.3°C (0.54°F) typical, 0.5°C (0.9°F) maximum
Error Over Temperature: 0.4°C (0.72°F) typical, 0.8°C (1.4°F) maximum
Nonlinearity TA = -25 to 105°C (-13 to 221°F): 0.05°C (0.09°F) typical, 0.15°C (0.27°F) maximum
Error Over Temperature: 0.5°C (0.9°F) typical, 1°C (1.8°F) maximum
Nonlinearity: 0.1°C (0.18°F) typical, 0.35°C (0.63°F) maximum
Output Characteristics
Nominal Current Output @ 25°C (298.2 K): 298.2 µA typical
Temperature Coefficient: 1 µA/°C typical
Repeatability: 0.1°C (0.18°F) typical
Long Term Stability: 0.1°C/month (0.18°F) typical
Absolute Maximum Ratings
Operating Temperature: -25°C (-13°F) minimum, 105°C (221°F) maximum
Package Temperature: -45°C (-49°F) minimum, 125°C (257°F) maximum
Forward Voltage (+ to -): 44V maximum
Reverse Voltage (- to +) Lead Temperature: 20V maximum
Soldering, 10 Seconds: 572°C (1062°F) maximum
Power Supply
Operating Voltage Range Power
Supply Rejection: 4V minimum, 30V maximum
4V < Vs < 5V: 0.5°C (0.9°F)/V maximum
5V < Vs < 15V: 0.2°C (0.36°F)/V maximum
15V < Vs < 30V: 0.1°C (0.18°F)/V maximum
The OM-2628 probe can be employed in applications between -25 and 105°C (-13 to 221°F) where conventional temperature sensors (i.e., thermistor, RTD, thermocouple, diode) are currently being used. Expensive linearization circuitry, precision voltage references, bridge components, resistance measuring circuitry and cold junction compensation are not required with the OM-2628 probe.
The OM-2628 solid state sensor is particularly useful in remote sensing applications, the AD592CN is immune to voltage drops and voltage noise over long lines due to its high impedance current output.
Specifications
Accuracy
Calibration Error @ 25°C (77°F) TA = 0 to 70°C (32 to 158°F): 0.3°C (0.54°F) typical, 0.5°C (0.9°F) maximum
Error Over Temperature: 0.4°C (0.72°F) typical, 0.8°C (1.4°F) maximum
Nonlinearity TA = -25 to 105°C (-13 to 221°F): 0.05°C (0.09°F) typical, 0.15°C (0.27°F) maximum
Error Over Temperature: 0.5°C (0.9°F) typical, 1°C (1.8°F) maximum
Nonlinearity: 0.1°C (0.18°F) typical, 0.35°C (0.63°F) maximum
Output Characteristics
Nominal Current Output @ 25°C (298.2 K): 298.2 µA typical
Temperature Coefficient: 1 µA/°C typical
Repeatability: 0.1°C (0.18°F) typical
Long Term Stability: 0.1°C/month (0.18°F) typical
Absolute Maximum Ratings
Operating Temperature: -25°C (-13°F) minimum, 105°C (221°F) maximum
Package Temperature: -45°C (-49°F) minimum, 125°C (257°F) maximum
Forward Voltage (+ to -): 44V maximum
Reverse Voltage (- to +) Lead Temperature: 20V maximum
Soldering, 10 Seconds: 572°C (1062°F) maximum
Power Supply
Operating Voltage Range Power
Supply Rejection: 4V minimum, 30V maximum
4V < Vs < 5V: 0.5°C (0.9°F)/V maximum
5V < Vs < 15V: 0.2°C (0.36°F)/V maximum
15V < Vs < 30V: 0.1°C (0.18°F)/V maximum
PDF et manuels
Afficher les notes et les avis
Rated 5 out of
5
by
AICG from
Dependable
We have used these for about a year now and they are performing well for us.
Date published: 2016-06-11
Rated 5 out of
5
by
Greg G from
IC Probe
Probes work well, no issues yet. I wish they had longer lead wire.
Date published: 2023-07-18
What kind of controller would accept this probe? 4-20ma? I am currently using a plc with a temperature module and a 100 ohm rtd sensor which is very vulnerable to noise. My sensor wire run is about 30ft.
Thank you for your question. Unfortunately, this probe was only used with an obsolete Data Acquisition board that interfaced with AD592 sensors and there is no controller available to monitor this sensor.
Date published: 2021-04-20