Délai de livraison (si pas en stock): 3 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Accuracy ± 0.1 %
Accuracy Note Current Accuracy: ±0.024 mA Voltage Accuracy: ±0.1 mV, ±0.01 V Thermistor Accuracy: ±0.50% RTD Accuracy: ±0.1 °C Thermocouple Accuracy: J, K, T, E, N: ±0.5 °C R, S, B: ±2.0 °C
Battery Size and Type 3.7V Li-ion
Calibration Factory calibration is recommended annually
Data Interface USB
Dimensions Note 6.65 in x 4.40 in x 1.41 in (168.9 mm x 111.8 mm x 35.8 mm) Data logger only
Display Note LCD Touchscreen: 5 inch LCD capacitive touchscreen.
Display Type LCD
Enclosure Ratings IP20
Frequency Input Range 0 to 25 kHz
Height 6.65 in
Impedance Input Current Input Impedance: 30Ω,Voltage Input Impedance: 1 GΩ,Frequency Input Impedance: 58 kΩ
Input Control Signal Millivolt input: -100 to 2450 mV Volt input: -0.5 V to 12.0 V
Input Current -5 to 50 mA
Input Type Thermocouple, RTD, Thermistor, Current,Voltage, Digital
Length 1.41 in
Materials Polycarbonate
Memory 1,000,000 or 5,000,000 Readings
Memory Note 1,000,000 or 5,000,000 Readings
Mounting Handheld, Tabletop or Wall Mounting
Number of Channels 8
Pulse Input Note 0 to 4,000,000,000 Pulses
Relative Humidity 0 to 95% RH non-condensing
Resolution 0.1 °C
Resolution Note Current Resolution: 0.0001 mA Voltage Resolution: 0.0001 mV, 0.0001 V RTD Resolution: 0.01 °C Thermisor Resolution: 0.01 °C Thermocouple Resolution: J, K, T, E, N: 0.1 °C R, S, B: 0.5 °C
Sampling Rate 4 kHz
Start Modes Delayed Start, Immediate Start
Supply Power Note • Rechargeable 3.7 V Lithium Ion Battery, • Continuous on-screen sampling: 9 hours; Stand-by mode: 100 hours
Supply Power Type USB
Temperature Measurement Range J: -200 to 760 °C,K: -270 to 1370 °C,T: -270 to 400 °C,E: -270 to 980 °C,R: -50 to 1760 °C,S: -50 to 1760 °C,N: -270 to 1300 °C,B: 50 to 1820 °C,RTD: -200 to 850 °C,TH 2252Ω, 10KΩ: -25 to 150°C
Thermocouple Type J, K, T, E, R, S, B, N
Weight 1.3 lb
Width 4.4 in
Wiring/Connector Table 2-, 4-Wire RTD
Voir toutes Spécs Montrer moins
Eight Channels Programmable Portable Data Logger OM-CP-OCTPRO OM-CP-OCTPRO
Rated 4 out of 5 by from Temperature Testing Overall impression is good! It is super easy to use, I did not even require the manual to get up and testing in 5 minutes. My only complaints are battery life for long data logging tests (you can leave plugged in to wall outlet just wish the battery lasted longer), the plug in connectors are a little difficult to install and remove, I wish I could view all channels at the same time on the graph, I wish I could adjust the scale of the graph and finally I wish it could record more channels.
Date published: 2020-07-29
Rated 1 out of 5 by from Completely broken after a few uses the analog board blew out according to an error message on the display after using only a few times. It was measuring fine but ended up just stopping and I haven't bee able to start it back up since then. It appears to be a $1000 broken piece of equipment. I'll see what Omega does to help fix this situation.
Date published: 2021-04-21
Rated 3 out of 5 by from Logger impressions after initial setup and use This device is very simple and functional, but has several shortcomings. The touchscreen sometimes is very insensitive and other times double hits, but it is useable. The data graph is very basic with very limited scaling and only 2 channels displayed. This device is adequate, but was expecting amazing at this price point.
Date published: 2020-11-11
Rated 4 out of 5 by from Field Engineer I bought this about two months ago and overall have been happy with it. There were a few times I had an error with programming when turning it on but was able to quickly fix the issue by just resetting it and have been able to log several different parameters and get the results I needed to. It coupled well with some of the pressure and temperature sensor we had available and the data and time stamping seemed accurate and easy to export. I think that this is a good versatile data logger for monitoring industrial issues.
Date published: 2020-05-22
Rated 5 out of 5 by from So easy to use!!! Let me preface my review by letting you know that I am an engineer employed at a large and very well-known chemical company. I purchased this data logger a few weeks ago to log pressure in my plant's fire water piping system. I have used many different data loggers in the past, but this one is by far the best and easiest I have ever used. My only complaint is that this data logger does not have a built-in power supply; however, considering how small this data logger is in comparison to others with an interactive visual display, how can I really complain.
Date published: 2019-03-06
Rated 1 out of 5 by from Tons of promise wrecked by poor UI and a buggy OS We needed a product to use on the road for some basic logging - some 4-wire RTD's and some analog channels. This seemed like a great way to avoid headaches for temporary setups. We've got a deep well of trust for Omega, having used Omega stuff for years and years. So this was a shoe-in. Out of the box, all was well. The interface draws a lot from modern smartphone conventions, which makes it super intuitive to figure out - I was logging 2 minutes after I opened it up. In the field though, things began to fall apart. During setup it would occasionally freeze up and need a power cycle. Fine, normal, but the power cycling takes a very long time (2-3 minutes at least) and the device doesn't tell you if it's turning off, turning on, if you've pressed the button long enough, etc. This was surprisingly frustrating. Many selections made on the touchscreen (such as reading interval) feature a "poke and pray" scrolling list, which would be too hard to use even on the newest phones. The screen itself has to be the poorest capacitive screen I've ever used. It almost feels like one of those old resisitive ones. Data cannot be removed during a logging session. Not a big deal, unless combined with the last and largest issue... Getting the thing to recognize a USB stick (including the one it comes with) is madness. Reboot, reboot with it plugged in, try a different stick, take it back to your PC and format it, reboot again, and MAYBE this time it will recognize it. It's an excellent toy if you want to mess around. But if data is equal to dollars, stay far away from this product.
Date published: 2020-01-24
Rated 4 out of 5 by from Gets the job done. It works well for what we need it to do, which is logging data from transmitters on the fly. I really enjoy being able to manually enter the sensor scaling to the outputs instead of only being able to see a raw mA or V output. The display is bright enough to be seen outside on a sunny day. Battery life seems to be sufficient for a full eight (8) hour day of intermittent data logging (5-10 minutes of actual logging every hour or so, the remainder of the time idle with the display on.) My only real gripe is that the high frequency logging (100 Hz - 4kHz) is only usable on a single channel. It would be extremely beneficial to be able to log at 100 Hz on at least two channels at the same time. This product, as far as I am aware, also does not have an onboard power supply to power measurement devices. Maybe this functionality is included somewhere, but I didn't see it in the manual and couldn't figure out how to configure it in any case. Would be a HUGE plus to not have to carry a separate power supply. The interface could also be snappier but it's never slow to the point that it obstructs workflow.
Date published: 2024-08-12
Rated 4 out of 5 by from The data logger stopped working. Dear all, I was using the equipment and it stoped to work. I've been using this equipment around 2 years in order to measure temperature (+ / - 120°C) and voltage (~ 0,980 V). Would it be possible to repair? If so, how? Thanks in advance.
Date published: 2023-06-26
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_9
  • loc_en_CA, sid_OM-CP-OCTPRO, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration