Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

RD45A-RD46A-Series
Single and Dual Channel 8 in Flatbed Recorders
- 14 calibres d'entrée de 1mV à 20Vcc
- HOME Function Returns Pen to Plot Start
- GRID Function Aligns Pen to Paper Grid
- Zero Suppression from –100 to 500%
- Even Marker Standard
- Electric Pen Lift and Remote Control Options
- Pen Offset Compensation Optional
RD45A-RD46A-Series
Depuis
C$
7,442.93

L'aperçu du produit
- Accuracy ± 0.3 %
- Accuracy Note Chart Timebase: ±50 ppm, Span Accuracy: 0.3% v
- Adjustments 40 to 100%
- Chart Length 25000 mm
- Chart Note Step Size: 0.050 mm
- Chart Speed 0.1, 0.2, 0.5, 1, 2, 5, 10, 20 mm/min or mm/sec
- Chart Width 200 mm
- CMRR 130 dB
- Deadband Recording: 0.2%
- Height 90 mm
- Impedance Input 1 MΩ dc; 10 kΩ in series with 1.5 µF for ac
- Length 290 mm
- Measurement Range Note Voltage: 1, 2, 5, 10, 20, 50, 100, 200, 500 mV; 1, 2, 5, 10, 20 Vdc; Input: Floating, non-symmetric, Input Terminals: 2 safety terminals, Max Input Voltage: 42 Vdc/30 Vac max at input terminals; (personal safety limits)
- Measurement Type Voltage
- Non-Linearity ± 0.3 %
- Operating Temperature, Max 40 °C
- Operating Temperature, Min -10 °C
- Pen Type Pen Lift
- Pen Type Note Electronic; automatic pen lift after 30 sec if chart is not advanced
- Recording Note Zero Position: User-selectable, left or right side
- Relative Humidity 35 to 85% RH
- Response Time 0.2 Sec
- Storage Temperature, Max 75 °C
- Storage Temperature, Min -40 °C
- Supply Power Note 110/220 Vac, switchable; -15/+20%; 50/60 Hz
- Supply Power Type AC
- Supply Voltage 110/220 Vac
- Thermal Zero Effect 1 µV/°C
- Voltage Measurement Range 0 to 1 mV, 0 to 2 mV, 0 to 5 mV, 0 to 10 mV, 0 to 20 mV, 0 to 50 mV, 0 to 100 mV, 0 to 200 mV, 0 to 500 mV; 0 to 1 Vdc, 0 to 2 Vdc, 0 to 5 Vdc, 0 to 10 Vdc, 0 to 20 Vdc
- Weight 3.5 kg
- Width 380 mm
- Zero Setting Adjustable Range -50 to 150% FS
The RD45A single channel and RD46A dual channel flatbed recorders are ideal instruments for use in research, development and production, as well as in service and education applications. Designed for ease of use, these recorders have an ergonomic shape which allows the user to easily write comments on the chart, even next to the pen.
The wide, 200 mm (8") chart is capable of recording measurements from 1 mV full scale to 20 V. Chart speeds from 0.1 mm/min to 20 mm/sec (1 mm = 0.03937") are available. The electric pen lift function will automatically lift the pens if the chart has not been advanced for 30 seconds this will lengthen pen life, as well as keep the chart paper clean and easy to read.
The RD45A and RD46A have built-in HOME and GRID functions.
The home function is useful for comparative measurements, where the chart is rewound automatically to the same starting point. The grid function moves the pen to an exact grid line on the chart, which allows for easy repetitive measurements. As an option, pen offset compensation is available. This eliminates the recording offset caused by the distance between the two pens.
The wide, 200 mm (8") chart is capable of recording measurements from 1 mV full scale to 20 V. Chart speeds from 0.1 mm/min to 20 mm/sec (1 mm = 0.03937") are available. The electric pen lift function will automatically lift the pens if the chart has not been advanced for 30 seconds this will lengthen pen life, as well as keep the chart paper clean and easy to read.
The RD45A and RD46A have built-in HOME and GRID functions.
The home function is useful for comparative measurements, where the chart is rewound automatically to the same starting point. The grid function moves the pen to an exact grid line on the chart, which allows for easy repetitive measurements. As an option, pen offset compensation is available. This eliminates the recording offset caused by the distance between the two pens.
PDF et manuels