HH501AS-BS-HH501AR-BR
1 Channel S Type Thermocouple High Temperature NEMA-4X Meter
Modèles en stock
- NEMA-4X Dustproof, Water/Splash Resistant
- Measures Very High Temperatures
- Warning Beeper with Hi/Lo Setting, Time Setting
- Clock and Elapsed Time
HH501AS-BS-HH501AR-BR
Depuis
C$
141.00
Modèles en stock

L'aperçu du produit
- Additional Features 1 MIN/MAX/REL/HOLD Functions , Auto Power-Off
- Battery Indication “+ -” is displayed when battery voltage drops below operating level
- Battery life 100 hr
- Differential Voltage, Max 1 V
- Display Type Note 3 1/2 digit liquid crystal display(LCD) with a maximum reading of 1999 Default Display Output : Zero : Automatic
- Electrical Connection Miniature Male Thermocouple Connector
- Height 195 mm
- Input Protection Voltage 24 V
- Input Protection Voltage Note 24V dc or 24V ac rms maximum input voltage on any combination of input pins.
- Length 53 mm
- Measuring Temperature Range, Max 1767 °C
- Measuring Temperature Range, Min 0 °C
- Number of Channels 1
- Operating Temperature Note 0°C to 50°C (32°F to 122°F)<80% RH
- Overrange -OL is displayed.
- Polarity Automatic, positive implied, negative polarity indication.
- Sampling Rate 1 Hz (1 update/second)
- Storage Temperature, Max 60 °C
- Storage Temperature, Min -20 °C
- Storage Temperature Note -20 to 60°C (-4°F to 140°F)<70% RH
- Temperature Accuracy ± 5 °C
- Temperature Accuracy Note Stated accuracy at 23°C± 5°C,<75% relative humidity
- Temperature Coefficient 0.1 times the applicable accuracy specification per °C from 0 to 18°C and 28 to 50°C (32 to 64°F and 82 to 122°F)
- Temperature Resolution 1 °C
- Weight 365 g
- Width 92 mm
HH501BR or HH501BS 1999 Counts Backlit LCD Display Models for Type R or S Thermocouple Input Reading HOLD, Max function Dual input with Differential Function T1-T2 | HH501AR or HH501AS 1999 counts Backlit LCD Display Models for Type Thermocouple Reading HOLD MAX function ITS-90 Accuracy Single Input |
Specifications | HH501AS | HH501BS | HH501AR | HH501BR |
Backlit LCD | • | • | • | • |
No. of Digits | 1999 | 1999 | 1999 | 1999 |
Probe (Type) | S | S | R | R |
Input Channel | 1 | 2 | 1 | 2 |
Range °C | 0-1787°C | 0-1767°C | 0-1767° | 0-1787°C |
Range °F | 32-1999°F | 32-1999°F | 32-1999 | 32-1999°F |
Resolution | 1° | 1° | 1° | 1° |
Data/Hold | • | • | • | • |
Max/Min | • | • | • | • |
Relative | • | • | • | • |
Hi/Lo Limits w/Beeper Warning | • | • | • | • |
Display | 1 | 1 | 1 | 1 |
T1-T2 | • | • | ||
Battery | 9 V | 9 V | 9 V | 9 V |
Auto Power Off | • | • | • | • |
Basic Accuracy % rdg | 0.1% +1°C | 0.1% +1°C | 0.1% +1°C | 0.1% +1°C |