Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

OME-PCI-1002
110 KS/s 12-Bit Low Cost A/D Boards
- PCI Bus
- 12-Bit 110 KHz A/D Converter
- 32 Single-Ended/16 Differential Inputs
- 110 KS/s Sampling Rate: OME-PCI-1002L-110KS/s OME-PCI-1002H-40KS/s (Single Channel or Multiple Channels)

L'aperçu du produit
The OME-PCI-1002 series is a family of PCI bus A/D boards. They feature a 110 KHz data acquisition under DOS and Windows. The boards provides 32 single-ended or 16 differential inputs, 16 digital input and 16 digital output channels. The -H means high gain model and the -L means low gain model. The OME-PCI-1002 series provides three flexible external trigger modes; post-trigger, pre-trigger, middle trigger.
Software Development Kit
All boards are supplied with a standard software development kit for Windows 98/NT/2000/XP. The software development kit includes DLL files for programming in C, C++ or other high level languages and OCX files for Visual Basic or Active X programming. LabView drivers are also included.
The OME-PCI-1002 includes 16-channels of digital input and 16-channels of digital output. A OME-DB-8025 screw terminal panel can be used to connect to the digital I/O lines. The OME-DB-16P isolated digital input board and OME-DB-16R relay board can be used to connect the digital I/O on the OME-PCI-1002 to real world signals.
Accessories
In order to connect to analog and digital signals a variety of terminal panels, digital input and relay boards are available for the OME-PCI-1002. See the Related Links section on this page for more details on these accessories.
Software Development Kit
All boards are supplied with a standard software development kit for Windows 98/NT/2000/XP. The software development kit includes DLL files for programming in C, C++ or other high level languages and OCX files for Visual Basic or Active X programming. LabView drivers are also included.
The OME-PCI-1002 includes 16-channels of digital input and 16-channels of digital output. A OME-DB-8025 screw terminal panel can be used to connect to the digital I/O lines. The OME-DB-16P isolated digital input board and OME-DB-16R relay board can be used to connect the digital I/O on the OME-PCI-1002 to real world signals.
Accessories
In order to connect to analog and digital signals a variety of terminal panels, digital input and relay boards are available for the OME-PCI-1002. See the Related Links section on this page for more details on these accessories.
OME-DB-1825 Screw Terminal Panel for Analog Input Channels.![]() | OME-DB-8025 Screw Terminal Panel for Digital Input Channels![]() | OME-ADP-20/PCI 20-pin Extender ![]() | ||
OME-DB-16P 16 Channel Isolated Digital Input Board ![]() | OME-DB-16R 16 Channel SPDT Relay Output Board ![]() |
Specifications ANALOG INPUT SPECIFICATIONS Channels: OME-PCI-1002H, OME-PCI-1002L: 32 single-ended/ 16 differential Resolution: 12 bits Conversion Rate: 40 KS/s max. Input Impedance: 10,000 M//6pF Overvoltage Protection: ±35V Accuracy: 0.01% of reading, ±1 bit Linearity: ±1 bit OME-PCI-1002H Input Ranges(High Gain)
OME-PCI-1002L Input Ranges(Low Gain)
| DIGITAL I/O Inputs: 16 channels; TTL levels Input Low: VIL = 0.8 V max, IIL = 4 mA Input High: VIH = 2.0 V min, IIH = -20 µA max Outputs: 16 channels; TTL levels Output Low: 0.5 V max, IOL = 4 mA max Output High: 2.7 V min, IOH = -400 µA max TIMER COUNTER Internal Pacer Timer: 16-bit, 8 MHz input External Pacer Timer: 16-bit, 8 MHz input Machine Independent Timer: 16-bit, 8 MHz input GENERAL ENVIRONMENTAL Operating Temperature: 0 to 50°C (32 to 122°F) Storage Temperature: -20 to 70°C (22 to 130°F) Humidity: 0 to 90% RH non-condensing Dimensions: 175 L x 105 mm H (6.9 x 4.1") Power Requirements: +5 V @ 350 mA (max) |