PX653

Highly Accurate, Low Pressure Laboratory Transducer

Modèles en stock
  • Clean Rooms
  • HVAC
  • Laboratory Fume Hoods
  • NIST Traceable Calibration Certificate
PX653
Depuis C$ 991.27
Modèles en stock
Highly Accurate, Low Pressure Laboratory Transducer PX653 PX653
loading all models
L'aperçu du produit
  • Accuracy Class > 0.25%
  • Applications Air and HVAC, Laboratories and Scientific
  • Burst Pressure 20 psi Maximum
  • Compensated Temperature, Max 57 °C
  • Compensated Temperature, Min 2 °C
  • Current Draw <5 mA
  • Electrical Connection Screw Terminal
  • Electrical Output Note 1 to 5 Vdc (3 wire)
  • Enclosure Ratings IP62, NEMA Type 2
  • Gauge Type Capacitance
  • Hysteresis 0.02% FS
  • Length 53 mm
  • Line/Static Pressure 25 psi
  • Linearity Error 0,005
  • Materials, Wetted Clean, Dry, Non-corrosive Gases
  • Operating Temperature, Max 72 °C
  • Operating Temperature, Min -29 °C
  • Pressure Type Differential
  • Process Connection Note 1 ⁄4 barbed fittings (tubing TY-316-100)
  • Process Connection Size 1/4 in
  • Proof Pressure Up to 15 psi
  • Repeatability Error 0.05% FS
  • Response Time 250 ms
  • Shunt Calibration Value NIST cal at 25, 50, 75 and 100% FS; upscale and downscale provided
  • Supply Voltage 12 to 36 Vdc
  • Thermal Effect on Zero error, Max 0.015% rdg/°F , 0.015% FS/°F
  • Weight 368 g
  • Width 117 mm
SPECIFICATIONS
Excitation: 12 to 36 Vdc
Output: 1 to 5 Vdc (3 wire)
Linearity: 0.3% FS (BFSL)
Hysteresis: 0.02% FS
Repeatability: 0.05% FS
Operating Temperature: -29 to 72°C (-20 to 160°F)
Compensated Temperature: 2 to 57°C (35 to 135°F)
Thermal Effects:
Zero: 0.015% FS/°F
Span: 0.015% rdg/°F
Proof Pressure: 15 psi
Burst Pressure: 20 psi
Static Pressure: 25 psi
Gage Type: Capacitance
Supply Current: <5 mA
Calibration Report: NIST cal at 25, 50, 75 and 100% FS; upscale and downscale provided
Response Time: 250 ms
Wetted Parts: Dry, clean, non-corrosive gases only
Enclosure: NEMA 2 (IP62), 107 H x 117 W x 53 mm D (4.2 x 4.6 x 2.1')
Pressure Port: ¼ barbed fittings (tubing TY-316-100)
Electrical Connections.: Screw terminal
Weight: 368 g (13 oz)
Rated 1 out of 5 by from Incorrect Calibration Analog Output (mA) was incorrect when compared to the Certificate of Calibration. The input of zero differential pressure gave an output of 3.9mA, not 4.0mA.
Date published: 2023-08-28
Rated 5 out of 5 by from Accurate pressure differential sensor. Highly accurate. Great instructions. The set up was very easy.
Date published: 2021-12-21
Rated 5 out of 5 by from Excellent Product! I'm really happy with the product we received. It will suit our needs perfectly
Date published: 2021-12-21
  • y_2025, m_2, d_20, h_9
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_PX653-0-05BD5V, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT

Does this sensor come with a meter as shown in the picture?

Asked by: haochey
Thank you for the inquire. The meter would be a separate purchase
Answered by: application engineer je
Date published: 2022-07-27

Are these sensors compatible with natural gas/methane?

Asked by: melectron
Thank you for your inquiry, this unit is designed to work with Dry, clean, non-corrosive gases only. If you're measuring natural gas or methane, we would recommend that you use a intrinsically safe sensor.
Answered by: rkent
Date published: 2021-10-15

What does (3 wire) output mean?

Asked by: shannon007
This is a 3 wire voltage output device. Wiring is as follows: The positive side of the power supply is connected to the V+ terminal. Both the negative side of power supply and the negative output signal are connected to the V- terminal. The positive output signal is connected to the OUT terminal.
Answered by: JK Applications Engineer
Date published: 2024-06-03
  • y_2025, m_2, d_21, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_3
  • loc_en_CA, sid_PX653-0-05BD5V, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 24ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration