  • Excellent Accuracy ±0.6°C T/C, ±0.3°C RTD 0.015% Electrical 0.05% Pressure
  • Read and Source Modes
  • 10 T/C Types  8 RTD types plus 400 Series Thermistor
  • Stores up to 9 setpoints for each output function
PCL1000-Series
Depuis C$ 2,649.80
PCL1000 SeriesHIGH ACCURACY MULTI-FUNCTION CALIBRATORWith RS232 Interface PCL1000-Series PCL1000-Series
loading all models
L'aperçu du produit
  • Battery life 25 hr
  • Battery Size and Type Alkaline AAA
  • Continuity Test 0 to 400.0 Ω; audible tone under 10 Ω
  • Data Interface RS232
  • Frequency CPM: Source 2 to 1000.0; measure 0 to 1000.0,Hz: Source 0 to 1000; measure 0 to 1000.0,kHz: Source 1 to 10.0; measure 0 to 10.00
  • Height 221 mm
  • Length 58 mm
  • Loop Supply Limits Voltage Drive: 1 mA
  • Current, Max 0 to 24 mA
  • Resistance 3200 Ω
  • RTD Input Note RTD Types: JIS, Ni120, Cu10; RTD IEX Range: 0.01 to 3 mA; RTD Frequency Response: 10 ms
  • RTD Type Pt 385 (100, 200, 500, 1 kΩ)
  • Thermistor Type Series 400
  • Thermocouple Type J, K, T, E, R, S, B, N, L, U
  • Voltage Note Low: 0 to 20.000 Vdc; read and source High: 0 to 250 Vdc or Vac; read only
  • Weight 0.9 kg
  • Width 107 mm
SPECIFICATIONS
Operational Temp Range:
0 to 50°C (14 to 122°F)
Stability:0.01% F.S./°C outside of 23°C± 5°C
Pressure Accuracy: 0.05% FS
Max Overpressure: 300%
Ports:<100 psi 1/4' barbed hose fittings,≠¤ 100 psi: 1/8' brass swagelok fittings
Wetted Parts: clean dry gases only
T/C Types: J,K,T,E,R,S,B,N,L,U
RTD Ranges: RTD Ranges: Pt385 (100, 200, 500, 1000Ω) Pt392, JIS, Ni120, CU10, YS1400
Ohm Ranges: 0 to 400.00 and 400.0 to 4000.0
Voltage:
(Low) I/O 0-20.000 V
(High) Input only 0-250 V ac/dc
Frequency: 0-1000.0 CPS, Hz 0-10.00 kHz
Continuity: 0 to 400.0Ω audible tone under 10Ω
Accuracy: T/C Type J: ± 0.3°C ± 10µV (± 0.6°C total error)
RTD Pt100: ± 0.1°C ± 0.075 Ω (± 0.3°C total error)
Ohms (400): ± 0.1 Ω
Ohms (4000): ± 1.0 Ω
mA Compliance: up to 1000 Ω
Voltage Drive: 1 mA
RTD IEX-range: 0.01 mA to 3 mA
RTD Frequency Response: 10 mS
Operating Temp: -10 to 50°C
Storage Temp: -40 to 60°C
Power: 4 AA alkaline batteries (included)
Dimensions: 191x102x38 mm(7.5x4x1.5')
Weight: 350g (12oz)

External Pressure Modules*
MODEL NO. Parameter Range Gauge (psig) Accuracy Over Pressure
PCL-PMA Pressure Module adaptor (one required)
PCL-PM030G 0 to 30 (0 to 2 bar) ± 0.025% 300%
PCL-PM050G 0 to 50 (0 to 3.5 bar) ± 0.03% 300%
PCL-PM100G 0 to 100 (0 to 7 bar) ± 0.025% 300%
PCL-PM300G 0 to 300 (0 to 20 bar) ± 0.025% 200%
PCL-PM1KG 0 to 1000 (0 to 70 bar) ± 0.05% 200%
PCL-PM3KG 0 to 3000 (0 to 200 bar) ± 0.1% 200%
PCL-PM5KG 0 to 5000 (0 to 340 bar) ± 0.1% 200%
PCL-PM015VAC 0 to -15 (0 to -1 mbar) ± 0.025%, ± 0.0025 psi 300%
PCL-PM015A 0 to 15 (0 to 1 bar) abs. ± 0.025%, ± 0.0025 psi 300%
PCL-PM030A 0 to 30 (0 to 2 bar) abs. ± 0.025% 300%
PCL-PM015C -15 to 15 (-1 to 1 bar) ± 0.025%, ± 0.0025 psi 300%
PCL-PM030C -15 to 30 (-1 to 2 bar) ± 0.025%, ± 0.0025 psi 300%
PCL-PM030D 0 to 30 (0 to 2 bar) diff. ± 0.025% 300%
* Most popluar ranges (see pressure module page for all ranges).
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

In the product image appears a handheld multiprocess calibrator and the product details correspond to a multiprocess calibrator, but the item# is for a pressure module. Is this a multiprocess calibrator or a pressure module?

Asked by: JavierSJ
Thank you for pointing this out. The image and specifications shown are for the PCL1000 Multifunction Calibrator. The part number and pricing indicated are for an accessory pressure input that can be used with this calibrator. This is an error on our our webpage which we will correct
Answered by: Applicatrions Engineer JK
Date published: 2021-01-28
  • y_2025, m_2, d_20, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_PCL1000, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration