MDS8PT
PLATINUM™ Series Universal Benchtop Digital Panel Meter
- UL and cUL Certified
- Universal Inputs
- Easy-to-Use and Configure
- High Quality & Accuracy
MDS8PT
Depuis
C$
1,301.04

L'aperçu du produit
- A/D Conversion 24-bit sigma delta
- Accuracy 0.03 % FS
- Additional Features 1 Programmable 3 Color Display
- CMRR 120 dB
- Configuration Differential
- Control Output 2 SPDT Relay
- Decimal Selection 0,001, 0,01, 0,1
- Digital Filter Programmable
- Display Size 21 mm (.82 in)
- Display Type Note 4 or 6 digit, 9-segment LED, 21 mm (0.83") GREEN, AMBER, and RED programmable colors for process variable, set point and temperature units
- Form factor Benchtop
- Frequency 50/60 Hz
- Input Current 4 to 20 mA, 0 to 24 mA
- Input Type Thermocouple, RTD, Thermistor, Current, Voltage
- Input Voltage -100 to 100 mV, -1 to 1 V, -10 to 10 Vdc
- Measurement Type Temperature, Current, Voltage, Differential Voltage
- Measuring Range Process Voltage: +100 mV, ±1, +10 Vdc;Process Current: Scalable within 0 to 24 mA;;Thermocouple:;Type J: -210 to 760°C;Type K: -270 to -160°C and -160 to 1372°C;Type T: -270 to -190°C and -190 to 400°C;Type E: -270 to -220°C and -220 to 1000°C;Type R: -50 to 40°C and 40 to 1768°C;Type S: -50 to 100°C and 100 to 1768°C;Type B: 100 to 640°C and 640 to 1820°C;Type C: 0 to 2320°C;Type N: -250 to -100°C and -100 to 1300°C;Type L: -200 to 900°C;;RTD:;Pt, 0.00385, 100, 500, 1000 Ω: -200 to 900°C;Pt, 0.00392, 100, 500, 1000 Ω: -200 to 850°C;;Thermistor:;2252 Ω: -40 to 120°C;5K Ω: -30 to 140°C;10K Ω: -20 to 150°C
- Number of Inputs 1
- Output Detail Optional Alarm 1 and 2 (Programmable) Type: Form “C” SPDT relays Operation: High/low, above/below, limited output to 30 Vrms, 60 Vdc max, band, latch/unlatch, normally open/ normally closed and process/deviation; front panel configurations Optional Analog Output (Programmable): Isolated, retransmission 0 to 10 Vdc or 0 to 20 mA, 500 Ω max (output 1 only). Accuracy is ± 1% of FS when following conditions are satisfied. 1) Input is not scaled below 1% of input FS 2) Analog output is not scaled below 3% of output FS
- Polarity Bipolar
- Resolution Temperature :1° /0.1° ; process : 10 µV
- RTD Input Range 100/500/1000 Ω Pt sensor, 2-, 3- or 4-wire; 0.00385 or 0.00392 curve
- Set Point Adjustment Menu Configurable
- Span Adjustment 0.001 to 9999 counts
- Step Response 0.7 sec for 99.9%
- Supply Power Type AC
- Supply Voltage 90 to 240 Vac
- Temperature Stability RTD: 0.04°C/°C ;TC@ 25°C (77°F): 0.05°C/°C ;Cold Junction Compensation Process: 50 ppm/°C
- Thermal Effects -9999 to +9999
- Thermistor Input Range 2252 Ω, 5K Ω, 10K Ω
- Thermocouple Type J, K, T, E, R, S, B, C, N, L
The OMEGAâ„¢ MDS8PT is a 1/8 DIN size (96 x 48 mm) digital panel meter in a benchtop plastic enclosure featuring the Pt Series color-changing display.
The Pt Series meters feature 4 or 6 digit LED displays that can be programmed to change color between GREEN , AMBER, and RED at any set-point or alarm point. Other options include isolated programmable analog output, serial communications, Modbus® and Ethernet. The universal temperature and process instrument handles 10 common types of thermocouples, thermistors, multiple RTD’s, and several process (DC) voltage and current ranges.
Specifications
Single-Channel Universal Inputs
Accuracy: See table for details
Resolution: 1°/0.1°; 10 µV process
Temperature Stability:
RTD: 0.04°C/°C
Thermocouple @ 25°C (77°F): 0.05°C/°C (cold junction compensation)
Process: 50 ppm/°C
CMRR: 120 dB
A/D Conversion: 24-bit sigma delta
Digital Filter: Programmable
Display: 4- or 6-digit, 9-segment LED, 21 mm (0.83") GREEN, AMBER, and RED programmable colors for process variable, set point and temperature units
Input Types: Thermocouple, RTD, thermistor, analog voltage, analog current
Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L
RTD Input (ITS 90): 100/500/1000? Pt sensor, 2-, 3- or 4-wire; 0.00385 or 0.00392 curve
Thermistor Input: 2252 ?, 5K ?, 10K ?
Voltage Input: -100 to 100 mV, -1 to 1 V, -10 to 10 Vdc
Current Input: 4 to 20 mA, 0 to 24 mA scalable
Configuration: Differential
Polarity: Bipolar
Step Response: 0.7 s for 99.9%
Decimal Selection: None, 0.1 for temperature; none, 0.1, 0.01 or 0.001 for process
Set-Point Adjustment: -9999 to 9999 counts
Span Adjustment: 0.001 to 9999 counts
Offset Adjustment: -9999 to +9999
Network and Communications
Ethernet: Standards Compliance IEEE 802.3 10/100
Supported Protocols: TCP/IP, ARP
RS232/RS485: Selectable from menu; both ASCII and Modbus protocol selectable from menu; programmable 1200 to 115.2 Kb; complete programmable setup capability; program to transmit current display, alarm status, min/ max, actual measured input value and status
Connection: USB connector on front panel; optional alarm 1 and 2 (programmable)
Optional Alarm 1 and 2 (Programmable)
Type: Form “C†SPDT relays
Operation: High/low, above/below, limited output to 30 Vrms, 60 Vdc max, band, latch/unlatch, normally open/ normally closed and process/deviation; front panel configurations
Optional Analog Output (Programmable):
Isolated, retransmission 0 to 10 Vdc or 0 to 20 mA, 500 ? max (output 1 only). Accuracy is ± 1% of FS when following conditions are satisfied.
1) Input is not scaled below 1% of input FS
2) Analog output is not scaled below 3% of output FS
General
Power: 90 to 240 Vac, 50 to 60 Hz
Note: Power cords for 120 Vac operation are available. See “Accessories.â€
The Pt Series meters feature 4 or 6 digit LED displays that can be programmed to change color between GREEN , AMBER, and RED at any set-point or alarm point. Other options include isolated programmable analog output, serial communications, Modbus® and Ethernet. The universal temperature and process instrument handles 10 common types of thermocouples, thermistors, multiple RTD’s, and several process (DC) voltage and current ranges.
Specifications
Single-Channel Universal Inputs
Accuracy: See table for details
Resolution: 1°/0.1°; 10 µV process
Temperature Stability:
RTD: 0.04°C/°C
Thermocouple @ 25°C (77°F): 0.05°C/°C (cold junction compensation)
Process: 50 ppm/°C
CMRR: 120 dB
A/D Conversion: 24-bit sigma delta
Digital Filter: Programmable
Display: 4- or 6-digit, 9-segment LED, 21 mm (0.83") GREEN, AMBER, and RED programmable colors for process variable, set point and temperature units
Input Types: Thermocouple, RTD, thermistor, analog voltage, analog current
Thermocouple Type (ITS 90): J, K, T, E, R, S, B, C, N, L
RTD Input (ITS 90): 100/500/1000? Pt sensor, 2-, 3- or 4-wire; 0.00385 or 0.00392 curve
Thermistor Input: 2252 ?, 5K ?, 10K ?
Voltage Input: -100 to 100 mV, -1 to 1 V, -10 to 10 Vdc
Current Input: 4 to 20 mA, 0 to 24 mA scalable
Configuration: Differential
Polarity: Bipolar
Step Response: 0.7 s for 99.9%
Decimal Selection: None, 0.1 for temperature; none, 0.1, 0.01 or 0.001 for process
Set-Point Adjustment: -9999 to 9999 counts
Span Adjustment: 0.001 to 9999 counts
Offset Adjustment: -9999 to +9999
Network and Communications
Ethernet: Standards Compliance IEEE 802.3 10/100
Supported Protocols: TCP/IP, ARP
RS232/RS485: Selectable from menu; both ASCII and Modbus protocol selectable from menu; programmable 1200 to 115.2 Kb; complete programmable setup capability; program to transmit current display, alarm status, min/ max, actual measured input value and status
Connection: USB connector on front panel; optional alarm 1 and 2 (programmable)
Optional Alarm 1 and 2 (Programmable)
Type: Form “C†SPDT relays
Operation: High/low, above/below, limited output to 30 Vrms, 60 Vdc max, band, latch/unlatch, normally open/ normally closed and process/deviation; front panel configurations
Optional Analog Output (Programmable):
Isolated, retransmission 0 to 10 Vdc or 0 to 20 mA, 500 ? max (output 1 only). Accuracy is ± 1% of FS when following conditions are satisfied.
1) Input is not scaled below 1% of input FS
2) Analog output is not scaled below 3% of output FS
General
Power: 90 to 240 Vac, 50 to 60 Hz
Note: Power cords for 120 Vac operation are available. See “Accessories.â€
Accessories
Afficher les notes et les avis
Rated 5 out of
5
by
Jayanth Jagadeesh from
Quality focused!
Quality product. met all expectation with no disappointment's.
Date published: 2024-04-15
Is there a flow chart for INIT? The manual does not have anything for adjust/calibration.
Thank you for the inquiry. Please reference the full manual of the DP8PT meter. Temperature calibration is in the last segment of the INIT menu.
https://assets.omega.com/manuals/M5460.pdf
Best regards
OMEGA
Date published: 2024-11-23
What is the webpage password for this device? I have searched for hours in all the manuals and can not find it.
Thank you for the inquiry. Default passwords are;
Login 12345678
Administrator 00000000
Best regards
OMEGA
Date published: 2021-08-12
Can the unit control a 12v fan and 200v/200w cartridge heater
If you need to Control devices you should get the CS8DPT which can control up to 240 VAC
Date published: 2020-07-29