CHF6

Process Water Circulation Heater

  • Standard Element Sheath Materials
  • Incoloy® 800 — A Nickel (30 to 35%), Chromium (19 to 23%), Iron alloy. The high nickel content of this alloy contributes to its resistance to scaling and corrosion. Used in air heating (also see Incoloy® 840) and immersion heating of potable water and other liquids that are not corrosive to an Incoloy® 800 sheath.
  • Low Carbon Steel — Applications include fluid heat transfer media, tar, high to low viscosity petroleum oils, asphalt, wax, molten salt, and other solutions not corrosive to a steel sheath.
  • 316 Stainless Steel — A Chromium (16 to 18%), Nickel (11 to 14%), Iron Alloy with Molybdenum (2 to 3%) added to improve corrosion resistance in certain environments, especially those that would tend to cause pitting due to the presence of chlorides. Applications include deionized water.
Process Water Circulation Heater CHF6 CHF6
loading all models
L'aperçu du produit
Surface Treatments for Stainless Steel and Incoloy® Elements and Other Wetted Parts to Improve Corrosion Resistance Flanged immersion heater surfaces in contact with the material being heated can be passivated or electro-polished to improve their resistance to corrosion. Passivation removes surface contamination, usually iron, so that the optimum corrosion resistance of the stainless steel is maintained. Surface contamination would come from the small amount of steel that may be worn off a tool during the manufacturing process. Passivating is accomplished by dipping the heater in a warm solution of nitric acid. Electro-Polishing is an electrochemical process that removes surface imperfections and contaminants, enhancing the corrosion resisting ability of the stainless steels. The resultant surface is clean, smooth and bright. Many medical and food applications require this finish.

8 watts/in2 (1.3 watts/cm2) — Typical Applications: Fuel Oils (Bunker C and Number 6)
Note: 3-Phase only. Cannot be rewired for single phase.
Nominal Pipe Size Dimensional Drawing Number KW Model Number Approx Weight
120V 240V-1Ph (C*) 240V-3Ph (C*) 480V-1Ph (C*) 480V-3Ph (C*) lb kg
21⁄2 NPT 3 elements 2.2 2 — — CHF01100(1) — CHF01101(1) 37 17
2.3 3 — — CHF01102(1) — CHF01101(1) 46 21
3"—150 lb 3 elements 3.2 2 — — CHF01104(1) — CHF01105(1) 62 28
3.3 3 — — CHF01106(1) — CHF01107(1) 76 34
(C*) = Number of Branch Circuits per heater
48 watts/in2 (7.5 watts/cm2)—Typical Applications: Process Water
Nominal Pipe Size Model Number Dim Drawing Number KW Approx Weight
120V 240V-1Ph (C*) 240V-3Ph (C*) 480V-1Ph (C*) 480V-3Ph (C*) lb kg
21⁄2 NPT 3 elements — CHF01694(1) CHF01695(1) CHF01696(1) CHF01697(1) 2.1 6 28 13
— CHF01698(1) CHF01699(1) CHF01700(1) CHF01701(1) 2.1 7.5 29 13
— CHF01702(1) CHF01703(1) CHF01704(1) CHF01705(1) 2.1 9 30 14
— — CHF01706(1) CHF01707(1) CHF01708(1) 2.2 12 37 17
— — CHF01709(1) CHF01710(1) CHF01711(1) 2.3 15 45 20
— — CHF01712(1) CHF01713(1) CHF01714(1) 2.3 18 46 21
3"—150 lb 3 elements — CHF01715(1) CHF01716(1) CHF01717(1) CHF01718(1) 3.1 6 53 24
— CHF01719(1) CHF01720(1) CHF01721(1) CHF01722(1) 3.1 7.5 53 24
— CHF01723(1) CHF01724(1) CHF01725(1) CHF01726(1) 3.2 9 61 28
— — CHF01727(1) CHF01728(1) CHF01729(1) 3.2 12 62 28
— — CHF01730(1) CHF01731(1) CHF01732(1) 3.3 15 74 34
— — CHF01733(1) CHF01734(1) CHF01735(1) 3.3 18 76 34
Ordering Example: CHF01708, 12 KW, 480 Vac, 3 phase circulation heater.
(C*) = Number of Branch Circuits per heater
Nominal Pipe Size Model Number Dim Drawing Number KW Approx Weight
120V 240V-1Ph (C*) 240V-3Ph (C*) 480V-1Ph (C*) 480V-3Ph (C*) lb kg
4"—150 lb 6 elements — CHF01736(1) CHF01737(1) CHF01738(1) CHF01739(1) 4.1 9 76 34
— CHF01740(2) CHF01741(1) CHF01742(1) CHF01743(1) 4.1 12 78 35
— CHF01744(2) CHF01745(1) CHF01746(1) CHF01747(1) 4.1 15 79 36
— CHF01748(2) CHF01749(1) CHF01750(1) CHF01751(1) 4.2 18 91 41
— CHF01752(2) CHF01753(2) CHF01754(2) CHF01755(1) 4.2 24 94 43
— — CHF01756(2) CHF01757(2) CHF01758(1) 4.3 30 117 53
— — CHF01759(2) CHF01760(2) CHF01761(1) 4.3 36 120 54
5"—150 lb 6 elements — CHF01762(2) CHF01763(2) CHF01764(2) CHF01765(1) 5.1 24 117 53
— — CHF01766(2) CHF01767(2) CHF01768(1) 5.2 30 128 58
— — CHF01769(2) CHF01770(2) CHF01771(1) 5.3 36 146 66
5"—150 lb 9 elements — — CHF01772(3) CHF01773(3) CHF01774(1) 5.1 36 123 56
— — CHF01775(3) CHF01776(3) CHF01777(3) 5.2 45 135 61
— — CHF01778(3) CHF01779(3) CHF01780(3) 5.3 54 154 70
6"—150 lb 12 elements — CHF01781(2) CHF01782(1) CHF01783(1) CHF01784(1) 6.1 18 124 56
— CHF01785(2) CHF01786(2) CHF01787(2) CHF01788(1) 6.1 24 127 58
— CHF01789(3) CHF01790(2) CHF01791(2) CHF01792(1) 6.1 30 129 59
— CHF01793(3) CHF01794(2) CHF01795(2) CHF01796(1) 6.2 36 152 69
— — CHF01797(4) CHF01798(3) CHF01799(2) 6.2 48 157 71
— — CHF01800(4) CHF01801(3) CHF01802(2) 6.3 60 197 89
— — CHF01803(4) — CHF01804(2) 6.3 72 202 92
6"—150 lb 15 elements — CHF01805(3) CHF01806(5) CHF01807(1) CHF01808(1) 6.1 23 126 57
— CHF01809(3) CHF01810(5) CHF01811(3) CHF01812(1) 6.1 30 130 59
— CHF01813(5) CHF01814(5) CHF01815(3) CHF01816(1) 6.1 38 132 60
— CHF01817(5) CHF01818(5) CHF01819(3) CHF01820(5) 6.2 45 156 71
— — CHF01821(5) CHF01822(3) CHF01823(5) 6.2 60 163 74
— — CHF01824(5) CHF01825(5) CHF01826(5) 6.3 75 204 93
— — CHF01827(5) — CHF01828(5) 6.3 90 211 96
8"—150 lb 18 elements — — CHF01829(3) CHF01830(3) CHF01831(2) 8.2 50 234 106
— — CHF01832(6) — CHF01833(2) 8.3 75 264 120
— — CHF01834(6) — CHF01835(3) 8.4 100 293 133
— — CHF01836(6) — CHF01837(6) 8.5 125 327 148
— — — — CHF01838(6) 8.6 150 360 163
— — — — CHF01839(6) 8.7 175 395 179
— — — — CHF01840(6) 8.7 200 405 184
8"—150 lb 24 elements — — CHF01841(4) CHF01842(3) CHF01843(2) 8.2 67 243 110
— — CHF01844(8) — CHF01845(4) 8.3 100 277 126
— — CHF01846(8) — CHF01847(4) 8.4 133 308 140
— — CHF01848(8) — CHF01849(8) 8.5 167 346 157
— — — — CHF01850(8) 8.6 200 382 173
— — — — CHF01851(8) 8.7 233 420 191
— — — — CHF01852(8) 8.7 267 433 196  
10"—150 lb 27 elements — — — — CHF01853(9) 10.3 225 539 244
— — — — CHF01854(9) 10.5 262 615 279
12"—150 lb 36 elements — — — — CHF01855(12) 12.3 300 694 315
— — — — CHF01856(12) 12.5 350 782 355
14"—150 lb 45 elements — — — — CHF01857(15) 14.2 315 771 350
— — — — CHF01858(15) 14.3 375 827 375
Ordering Example: CHF01788, 24 KW, 480 Vac, 3 phase circulation heater.
(C*) = Number of Branch Circuits per heater
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Hello there, I was wondering if I can use this unit (CHF01743) as an electrical tankless hot water heater. Would it be acceptable in Canada? Equipment code compliance? CSA

Asked by: Bilal
Thank you for your inquiry. This product is not compliant with CSA.
Answered by: CB Engineer
Date published: 2021-03-22
  • y_2025, m_4, d_13, h_16CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_CHF01703, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 7ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration