Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici
FMA-4105

Ajouté à votre panier
Configuration terminée.
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Veuillez ajouter au panier pour la conserver ou quitter la configuration
Échec de l'enregistrement des configurations, cliquez sur le bouton Configurer Recommencer
Spécifications du produit
<< Voir toutes les modèles de produitsBrand |
![]() |
Accuracy | ± 1 % |
Accuracy Note | ± 1% of FS at calibration temperature and pressure |
Altitude Sensitivity | Deviation of up to 1% from stated accuracy, after re-zeroing |
Calibration | NIST 10-Point Certificate |
Compliance | CE |
Data Interface | RS232 |
Display Type | None |
Electrical Output | 4 to 20 mA, 0 to 5 Vdc |
Enclosure Ratings | Inst. Level II/Poll. Degree II (IEC 60664) |
Humidity Range | Up to 70% |
Leak Rate Under Vacuum | less than 10^⁻9 cc He/s |
Materials, Wetted | 316 Stainless Steel, Aluminum, Brass, FKM |
Media Compatibility | Air, Gases, Nitrogen, Oxygen |
Operating Pressure, Max | 500 psi |
Operating Pressure, Min | 0 psi |
Operating Temperature, Max | 50 °C |
Operating Temperature, Min | 5 °C |
Output Detail | Linear 0 to 5 Vdc (3000 Ω min load impedance); Linear 4 to 20 mA (500 Ω max loop resistance). Max noise 20 mV peak to peak (for 0 to 5 Vdc output) |
Output Signal | Current, Voltage |
Power Consumption | 2.4 W |
Pressure Coefficient | 0.01% FS/psi |
Pressure Drop, Max | 0.18 psi |
Process Connection Size | 1/4 in |
Process Connection Type | Compression Fitting |
Repeatability | ± 0.15% |
Response Time | 2 sec |
Response Time Note | 600 ms time constant; approximately 2 seconds to within ± 2% of set flow rate for 25 to 100% of full scale flow |
Supply Power Note | Transducer Input Power: 11 to 26 Vdc, 100 mV max peak to peak output noise |
Supply Voltage | 11 to 26 Vdc |
Switch Rating | 30 Vdc, 1A |
Switch Type | SPDT NO/NC, Selectable |
Temperature Coefficient | 0.15% FS/°C |
Turndown Ratio | 50:1 |
Volumetric Flow Rate, Max | 50 SCCM |
Volumetric Flow Rate, Min | 0.1 SCCM |
Voir toutes Spécs |
PDF et manuels
Afficher les notes et les avis
Rated 1 out of
5
by
Very Unhappy from
Not happy with support and product received
The first unit came in without the digital display I needed and I had to reorder. The second arrived without a field functional power supply.
Only pigtails to plug into a power supply. Also, not what I wanted. I will rethink using your products in the future.
Date published: 2016-11-01
Rated 5 out of
5
by
Robert Shiner from
Order promptness
I purchased the item for a corporate buyer but he was pleased that what was ordered was what was delivered and he also commented on the quickness of the processing of the order.......
Date published: 2022-10-14
Rated 5 out of
5
by
Yasir A from
Simple and Accurate.
Install this on to measure the flow in a tube and nozzle as a testing fixture. The relays were used to set the good part to pass and were helpful. Only problem was the software was not available online and very limited. Made our own C# data acquisition software using RS232c cable and recorded values in CSV file.
Also I will recommend to use LCD version, because you may need to see the live reading.
Date published: 2021-12-21