Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

CL510A-Series

PT100 & PT1000 RTD Simulators with multiple or single curves

Modèles en stock
  • Source One or Multiple RTD Curves
  • High Accuracy
  • Easy-to-Read Backlight Display
  • Calibrate Directly in Temperature (°C or °F)
CL510A-Series
Depuis C$ 1,406.90
Modèles en stock
PT100 & PT1000 RTD Simulators with multiple or single curves CL510A-Series CL510A-Series
loading all models
L'aperçu du produit
  • Accuracy ± 0.015 %
  • Accuracy Note ± (0.015% of reading + 0.05 Ω)
  • Battery Indication A low battery indication is displayed when the battery voltage drops below the operating level
  • Battery life 50 hr
  • Display Type LCD
  • Display Type Note High contrast graphic liquid crystal display, LED backlighting for use in low lit areas
  • Height 45 mm
  • Length 126 mm
  • Operating Temperature, Max 60 °C
  • Operating Temperature, Min -25 °C
  • Over-Voltage Protection Over-voltage protection to 60 Vdc (rated for 30 sec)
  • Relative Humidity, Max 0.9
  • Relative Humidity, Min 10%
  • Relative Humidity Note Relative Humidity Range, 10% ≤RH: ≤90%: 0 to 35°C (32 to 95°F), non-condensing ≤70%: 35 to 60°C (95 to 140°F), non-condensing
  • Supply Voltage 6 Vdc
  • Temperature Drift ± 0.05 Ω/°C
  • Voltage Source Accuracy: From 1 to 10.2 mA External Excitation Current: ± (0.015% of rdg + 0.05 Ω) Below 1 mA of External Excitation Current: ± (0.015% of rdg + 0.01 mV/mA excitation current + 0.05 Ω) Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 Ω Allowable Excitation Current Range, Steady or Pulsed/Intermittent: <410 Ω: 10.2 mA max 410 to 001 Ω: 1 mA max Pulsed Excitation Current Compatibility: DC to 0.01 second pulse width
  • Weight 0.24 kg
  • Weight Note 0.24 kg (8.4 oz) (including batteries)
  • Width 69 mm

The CL510A RTD Simulator Series can check and calibrate all your RTD instruments. Take it into the shop, plant or field without worry. It’s easy to operate even in the dark areas of the plant with the backlit display. Stop carrying around a decade box and RTD resistance tables, with the CL510A you can calibrate directly in temperature (°C and °F). Choose between a single RTD type model, CL510A-1 (Pt100, 0.00385), or a CL510A-10 for multiple RTD types.

The CL510A-10 works with a wide variety of RTD curves including Platinm 100 (alpha = 3850, 3902, 3916, 3926) and 1000 (alpha = 3850, 3750) ?, Copper 10 and 50 ?, Nickel 100 and 120 ?. Easily set any value quickly to within 0.1° with the adjustable digital potentiometer "DIAL". Connect directly to RTD inputs of smart transmitters, PLCs, controllers and multichannel recorders and verify their displays.

SPECIFICATIONS (Unless otherwise indicated, all specifications are rated from a nominal 23°C (73°F), 70% RH)
Accuracy: ± (0.015% of Rdg + 0.05 ?)
Temperature Drift: ± 0.05 ?/°C
Operating Temperature Range: -25 to 60°C (-10 to 140°F)
Relative Humidity Range, 10% ?RH:
?90%: 0 to 35°C (32 to 95°F), non-condensing
?70%: 35 to 60°C (95 to 140°F), non-condensing
Size: 126 L x 69 W x 45 mm H (4.96 x 2.73 x 1.79")
Weight: 0.24 kg (8.4 oz) (including batteries)
Batteries: 4 "AA" alkaline 1.5V (included)
Battery Life: 50 hr
Low Battery: Low battery indication with nominal 1 hour of operation left
Protection Against Misconnection: Over-voltage protection to 60 Vdc (rated for 30 sec)
Display: High contrast graphic liquid crystal display, LED backlighting for use in low lit areas

Source
Accuracy: From 1 to 10.2 mA
External Excitation Current: ± (0.015% of rdg + 0.05 ?) Below 1 mA of External
Excitation Current: ± (0.015% of rdg + 0.01 mV/mA excitation current + 0.05 ?)
Resistance Ranges: 0.00 to 410.00, 410.1 to 4001.0 ?
Allowable Excitation Current Range, Steady or Pulsed/Intermittent:
<410 ?: 10.2 mA max
410 to 001 ?: 1 mA max Pulsed Excitation Current
Compatibility: DC to 0.01 second pulse width

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 23ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

Does this RTD Simulator come with a NIST traceable certificate?

Asked by: Rizl
The CL510A series do come with a NIST Certificate without temperature points.
Answered by: ApplicationEngineerANB
Date published: 2021-07-28
  • y_2025, m_2, d_19, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_CA, sid_CL510A-1, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 72ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration