Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

FMG70B-Series
Pulse or Current Output Low Flow Electromagnetic Flow Meter
Modèles en stock
- No Moving Parts
- No Flow Obstructions
- Maintenance-Free
- Fast Response Time (< 500 ms)
FMG70B-Series
Depuis
C$
2,221.90
Modèles en stock

L'aperçu du produit
- Accuracy ± 1.5 %
- Accuracy Note ± 1.5% of reading ± 0.3% range
- Conductivity 50 µS/cm
- Electrical Connection M12 4 pin Female
- Enclosure Ratings IP65, NEMA Type 4X
- Flow Indication LED Green
- Flow Indication Note flow proportional blinking
- Load Resistance 250 Ω
- Materials PEEK, Aluminum
- Materials, Wetted EPDM, Stainless Steel
- Current, Max 26_ma_approx
- Media Compatibility Acid Solutions, Conductive Liquids, Saltwater
- Number of Outputs 1
- Operating Pressure, Max 232 psi
- Operating Temperature, Max 70 °C
- Operating Temperature, Min 5 °C
- Output Detail Amplified Square Wave
- Output Pulse Rate Note Square wave signal NPN, internal pull-up resistor 2 kΩ pulse duty ratio 50:50
- Power Consumption 150 mA
- Process Temperature, Max 90 °C
- Process Temperature, Min 0 °C
- Repeatability ± 1%
- Response Time < 500 ms
- Short-Circuit Protected < 30 V
- Short-Circuit Protected Note Measures short-circuit proof (up to 30V) and polarity protection (up to -30V)
- Supply Power Note 24 Vdc ± 10%
- Supply Power Type DC
- Supply Voltage 24 Vdc
The FMG70B Series from OMEGA is a trio of extremely compact, low cost, inductive magnetic flow sensors. This product line allows a unique and highly reliable measuring technique to be introduced into areas of process control previously considered not possible.
Changes of temperature, density, viscosity, concentration or electrical conductivity (minimum conductivity of 50 µs/cm) of the fluid do not affect the output signal.
FMG70B series can be used in areas where flow sensors with moving parts e. g. paddle wheel sensors, cannot be applied due to contamination/particulate in the media. The sensor is intended for continuously measuring of flow rates or for dosing/batching of electrically conductive liquids (minimum conductivity 50 S/cm). The output signal frequency (or current) is proportional to the flow. Two options are available for output signals, frequency or analog (-A models).
Specifications
Materials of Construction
Electrodes and Process Connection: Stainless steel 316 TI
Measuring Pipe: PEEK-GF30
Gasket: EPDM
Housing: Cast Aluminum
Accuracy: ± 1.5% of reading ± 0.3% range
Repeatability: 1%
Minimum Conductivity: 50 µs/cm
Maximum Liquid Temperature: 90°C (194°F)
Ambient Temperature: 5 to 70°C (41 to 158°F)
Maximum Pressure: 16 bar (232 psi)
Flow Indication: LED green, flow proportional blinking
Frequency: Square wave signal NPN, internal pull-up resistor 2 k? pulse duty ratio 50:50
Signal Current Maximum: 20 mA, current limited
Response Time: <500 mS
Electrical Connection: Plug connector M12 x 1
Power Supply: 24 Vdc ± 10%
Current Consumption: Maximum 150 mA
Electrical Protection: Measures short-circuit proof (up to 30V) and polarity protection (up to -30V)
Protection Class: NEMA 4X (IP65)
Flow Range:
FMG71B: 0.5 to 30 LPM (0.13 to 7.93 GPM)
FMG72B: 1 to 60 LPM (0.26 to 15.85 GPM)
FMG73B: 5 to 250 LPM (1.32 to 66 GPM)
Analog Output Signal (“-A” Models) 4 to 20 mA (0 to Full Scale):
Current Limitation: 26 mA approx.
Maximum Load: 250 ? to GND
Changes of temperature, density, viscosity, concentration or electrical conductivity (minimum conductivity of 50 µs/cm) of the fluid do not affect the output signal.
FMG70B series can be used in areas where flow sensors with moving parts e. g. paddle wheel sensors, cannot be applied due to contamination/particulate in the media. The sensor is intended for continuously measuring of flow rates or for dosing/batching of electrically conductive liquids (minimum conductivity 50 S/cm). The output signal frequency (or current) is proportional to the flow. Two options are available for output signals, frequency or analog (-A models).
Specifications
Materials of Construction
Electrodes and Process Connection: Stainless steel 316 TI
Measuring Pipe: PEEK-GF30
Gasket: EPDM
Housing: Cast Aluminum
Accuracy: ± 1.5% of reading ± 0.3% range
Repeatability: 1%
Minimum Conductivity: 50 µs/cm
Maximum Liquid Temperature: 90°C (194°F)
Ambient Temperature: 5 to 70°C (41 to 158°F)
Maximum Pressure: 16 bar (232 psi)
Flow Indication: LED green, flow proportional blinking
Frequency: Square wave signal NPN, internal pull-up resistor 2 k? pulse duty ratio 50:50
Signal Current Maximum: 20 mA, current limited
Response Time: <500 mS
Electrical Connection: Plug connector M12 x 1
Power Supply: 24 Vdc ± 10%
Current Consumption: Maximum 150 mA
Electrical Protection: Measures short-circuit proof (up to 30V) and polarity protection (up to -30V)
Protection Class: NEMA 4X (IP65)
Flow Range:
FMG71B: 0.5 to 30 LPM (0.13 to 7.93 GPM)
FMG72B: 1 to 60 LPM (0.26 to 15.85 GPM)
FMG73B: 5 to 250 LPM (1.32 to 66 GPM)
Analog Output Signal (“-A” Models) 4 to 20 mA (0 to Full Scale):
Current Limitation: 26 mA approx.
Maximum Load: 250 ? to GND
PDF et manuels
Accessories
Afficher les notes et les avis
Is there a 4-20mA version of the FMG71B available? The datasheet says there is but the website shows no such thing.
Ordering with part number FMG71B-A results in "Part not found".
Date published: 2019-10-09
Is the 4-20mA version (FMG71B-A) a 2-wire or 3-wire? The data sheet, the manual and the pinout diagram on the part do not make this distinction clear.
Than kyou for your inquiry. Please email the Flow Group at flow@dwyeromega.com and will send the information regarding the correct PINS.
Date published: 2024-06-18