Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

M12TX

RTD probes with 4 to 20 mA Analog Output and M12 Connector

Modèles en stock
  • Programmable Transmitter
  • Molded Connector (IP67)
  • M12 Connection
  • 4 to 20 mA Output = 0 to 150°C Default Setting
M12TX
Depuis C$ 170.16
Modèles en stock
RTD probes with 4 to 20 mA Analog Output and M12 Connector M12TX M12TX
loading all models
L'aperçu du produit
  • Accuracy Class A
  • Body Material Thermoplastic
  • Downscale 3.6 mA
  • Electrical Output 4 to 20 mA
  • EMC In accordance to EN 61326
  • Enclosure Ratings IP67
  • Enclosure Ratings Note IP65 and IP67 in accordance to IEC60529
  • Factory Setting 0 to 150°C/sensor break >21 mA (upscale)
  • Operating Temperature, Max 80 °C
  • Operating Temperature, Min -40 °C
  • Permissible Load 700
  • Permissible Load Note 700 @ 24 Vdc [RLo= (Vsupply-8.5)/0.020]
  • Process Connection Size N/A
  • Process Temperature, Max 500 °C
  • Process Temperature, Min -50 °C
  • Range Configurations Note It is possible set the input temperature range (span) by the M12TX-CONFIG-SETconfiguration kit (PC with OS Windows® required)
  • Relative Humidity, Max 1
  • Relative Humidity, Min 0%
  • Response Time < 50 ms
  • RTD Type 100 Ω Pt Sensor
  • Sensor Break Monitoring Note Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
  • Sensor Error Compensation Note Over 2 points (maximum 1% of span)
  • Span, Min 50°C
  • Span Note 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
  • Supply Power Effects Negligible
  • Supply Voltage 8.5 to 32 Vdc
  • Temperature Influence, Max ± 0.3%
  • Temperature Influence Note Maximum of ± 0.3°C/25°C (77°F) or ± 0.3% of span/25°C (77°F)
  • Temperature Sensor Type RTD
  • Thermocouple Type N/A
  • Tmax. Electronic 80°C
  • Upscale 21 mA
  • Zero Setting Adjustable Range Any value between -50 to 50°C (-58 to 122°F)
The M12TX 100Ω RTD sensor with built-in transmitter can be programmable by a computer. The configuration kit required for programming is M12TX-CONFIG. This unique probe is ideal for areas with space limitations where traditional head connections are too large to fit. The M12 thread design offers a secure industrial connection. The temperature Transmitter is designed with mineral insulated cable probe (MgO) which allows the probe to have a minimum bend radius of three times the diameter.

Specifications
Body: Thermoplastic material
Probe Type: Compact mineral insulated cable AISI 316L SS
Probe Minimum Bending Radius: Three-times the outer diameter [except the sensing tip which length is 30 mm (1.2')]
Connection: M12x1 male in accordance to VDE0627 (output connection)
Sensor: RTD Pt100 class A up to 300°C in accordance to IEC751
Range: -50 to 500°C (-58 to 932°F)
Tmax. Electronic: 80°C (176°F)
Sensor Break Monitoring:
Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action
Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
Output
Signal: 4 to 20 mA
Permissible load: 700 @ 24 Vdc [RLo= (Vsupply-8.5)/0.020]
Response Time (90%): <50 ms
Isolation In-Out: Non-isolated
Power Supply: 8.5 to 32 Vdc (polarity protected)
Environment Conditions
Temperature: -40 to 80°C (-40 to 176°F) for plastic body
Relative Humidity: 0 to 100%
EMC: In accordance to EN 61326
Degree of Protection: IP65 and IP67 in accordance to IEC60529
Accuracy
Transmitter: Maximum of ± 0.2°C or ± 0.2% of span
Sensor: Class A in accordance to IEC751
Temperature Influence [Deviation from 20°C (68°F)]: Maximum of ± 0.3°C/25°C (77°F) or ± 0.3% of span/25°C (77°F)
Supply Voltage Influence: Negligible
Range Configurations: It is possible set the input temperature range (span) by the M12TX-CONFIG configuration kit (PC with OS Windows® required)
Zero Adjustments: Any value between -50 to 50°C
Minimum Span: 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
Sensor Error Compensation: Over 2 points (maximum 1% of span)
Factory Setting: 0 to 150°C/sensor break >21 mA (upscale)
Response Time: Diameter 3 mm <3.5 second, diameter 6 mm <13 second (test in water to IEC751- time for reaching 63.2% of instantaneous temperature change) three times the diameter.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 81ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
fr
Enregistrer la configuration