Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

RTD-810-Series

RTD Probes with Mounting Threads and Lead Wire

Modèles en stock
  • Sensor Contains a Precision 100 Ohm Class A DIN Platinum Element
  • Temperature Coefficient (Alpha) = .00385 ohm/ohm/°C
  • 3-Wire Configuration with PFA Insulated and Jacketed Lead Wire and Miniature 3-Pin Connector with Mating Connector
  • Temperature Range -200 to 750ºC (Cable to 260ºC)
RTD-810-Series
Depuis C$ 208.14
Modèles en stock
RTD Probes with Mounting Threads and Lead Wire RTD-810-Series RTD-810-Series
loading all models
L'aperçu du produit
  • Accuracy Class A
  • Insulation PFA
  • Nominal Resistance 100 Ω
  • Nominal Resistance/Curve Note Provided with High-Accuracy Class “A” 100 Ω Element (Standard)
  • Number of Wires 3
  • Probe Diameter 0.125 in
  • Probe Length 4.5 in
  • Probe Type High-Accuracy Fluid Immersion RTD Sensors
  • Process Connection Size 1/8 in
  • Process Connection Type NPT Male
  • Sensing Element 100 Ω Class “A” DIN Platinum Element
  • Sheath Material 304 Stainless Steel
  • Temperature Probe Style Immersion Probe
  • Temperature Sensor Type RTD
  • Wire Gauge 26 AWG
  • Wire Type Stranded
This immersion sensor has a closed ended stainless steel tube, 1/8NPT mounting fitting, 100 Ohm Class A DIN platinum element with PFA insulated & jacketed leads and miniature connector. Its rugged design is ideally suited for fluid measurements and pressurized systems where the sensor must mount into a threaded port. With a maximum temperature rating of 750ºC, this sensor can be used in a wide variety of applications. Combine the RTD-810 with any of the Omega extension cables, hand-held meters, controllers, displays or thermometers to form a complete measurement and control system.
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;

What is the maximum pressure rating of this probe?

Asked by: Joe_M
Hi Joe Please contact our Temperature Engineering for specifications relevant to pressure applications. Best regards OMEGA
Answered by: NorwalkAE_RS
Date published: 2020-08-14

What is the outside diameter of jacket of RTD-810 cable?

Asked by: Rajeshkumar S
The nominal OD of the lead wire is 0.072"
Answered by: ApplicationEngineerANB
Date published: 2024-04-24
  • y_2025, m_2, d_22, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_CA, sid_RTD-810, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 8ms
  • QUESTIONS, PRODUCT
fr-CA
fr
Enregistrer la configuration