Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

CNI-CB120SB-J

Microprocessor-based Controller Self container Temperature controller

C$1,427.65

Article# CNI-CB120SB-J

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$1,427.65
5-9 C$1,356.27
10-24 C$1,284.89
25-49 C$1,213.50
50-99 C$1,142.12
100+ C$1,070.74

En stock

Délai de livraison (si pas en stock): 3 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Additional Features 1 12A (1440 W) Capacity
Control Output 2 SPST Relay
Data Interface None
Display Type 3.5 Digit Display
Height 203 mm
Input Type Thermocouple, RTD, Voltage, mA
Length 152 mm
Measurement Type Current, Temperature, Voltage
Number of Control Outputs 2
Number of Inputs 1
Operating Temperature, Max 55 °C
Operating Temperature, Min 0 °C
Output Detail Two 15A Controlled Output Relays
Output Signal None
Power Consumption 3 W
Supply Power Type AC
Supply Voltage 120 Vac
Thermocouple Type J
Weight 4.53 kg
Voir toutes Spécs Montrer moins
Microprocessor-based Controller Self container Temperature controller CNI-CB120SB-J CNI-CB120SB-J

Accessories

Field Mountable M8 and M12 Connectors
C$25.30
922 In Stock
Rated 3 out of 5 by from Blends well with my design I operate a press with this control. I only wish there were more than one input.
Date published: 2017-03-01
Rated 4 out of 5 by from Useful It has Been working fine so far. We use them in our test stands.
Date published: 2023-05-07
Rated 1 out of 5 by from Not safe, poorly engineered. Looking at the documentation and diagrams, this unit has no 3rd party approvals, and I see why. The documentation says it has devices rated 20amps in the manual, yet the rated output for the 120V version is 25 amps. Looking at wiring diagrams, control circuit fusing is in the wrong location, and incorrect style of fuses are used. Either someone needs to review and update the documentation, or the units need to be redesigned by someone who knows control panels.
Date published: 2018-07-17
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_CNI-CB120SB-J, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration