Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

OMYL-RH25-Series

Temperature/Humidity Data Loggers with 2 External Inputs

Modèles en stock
  • Integral Temperature/Humidity Sensors
  • Plus 2 External Inputs for Temperature (Pt100/Pt1000 RTD/Thermistor) or Temperature/Humidity Probes
  • Up to 4 Million Readings (Internal Memory Size)
  • Up to 4 Hz Sampling Rate
OMYL-RH25-Series
Depuis C$ 805.00
Modèles en stock
Temperature/Humidity Data Loggers with 2 External Inputs OMYL-RH25-Series OMYL-RH25-Series
loading all models
L'aperçu du produit
  • Additional Features 1 Shock Proof, IP65 Housing
  • Battery life 25 hr
  • Battery Size and Type 3V Li-ion
  • Data Interface USB
  • Data Interface Note USB (interface cable included)
  • Diameter 50 mm
  • Enclosure Acetal
  • Enclosure Ratings IP65
  • External Temperature Resolution 0.01 °C
  • Height 30 mm
  • Internal Temperature Resolution 0.01 °C
  • LED Indicators Integrated status LED indicates data logging status, low battery or alarm condition
  • Measurement Type Relative Humidity, Temperature
  • Memory 100000
  • Memory Modes Yes
  • Number of Measurements 4
  • Operating Temperature, Max 70 °C
  • Operating Temperature, Min -30 °C
  • Process Temperature, Max 250 °C
  • Process Temperature, Min -70 °C
  • Relative Humidity, Max 1
  • Relative Humidity, Min 0%
  • Sampling Rate 1 Hz (1 update/second)
  • Sampling Rate Note 1 second to 24 hours; 2 Hz, 4 Hz in fast mode
  • Software Compatibility XP SP3/Vista/7 and 8 (32-bit and 64-bit)
  • Start Modes Delayed Start, Immediate Start
  • Supply Power Type Battery
  • Temperature Sensor Type RTD or Thermistor
  • Temperature Sensor Type Note Pt100 or Pt1000 RTD
  • Weight 70 g
The OMYL-RH25 is a temperature/humidity data logger that also accepts two external temperature or temperature/humidity inputs. This data logger is available with standard memory of 100,000 readings (OMYL-RH25) or expanded memory of 4 million readings (OMYL-RH25-4M). The following inputs can be configured:

• Internal temperature and humidity sensors
• External temperature (Pt100/Pt1000 RTD, Type U thermistor)
• External temperature/humidity (for combined external temperature/humidity probes)

The storage medium is non-volatile flash memory so no data is lost if the battery becomes discharged. Data logger setup as well as data retrieval is accomplished using the included standard OMYL-SOFT software. Downloaded data is stored in the OMYL-SOFT software as a text file for viewing in third party software packages or Microsoft Excel. The OMYL-SOFT standard software does not include any graphing functionality. Graphing and analyzing downloaded data files requires the OMYL-SOFT-PLUS version of the software (sold separately).

SPECIFICATIONS
Internal Temperature
Temperature Range: -30 to 70°C (-22 to 158°F) with standard lithium battery; -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery
Temperature Resolution: 0.01°C (0.02°F)
Accuracy: See chart on PDF
External Temperature Input
Sensor: Pt100 or Pt1000 RTD, U thermistor (2000Ω @ 25°C)
Range: -70 to 250°C (-94 to 482°F)
Resolution: 0.01°C (0.02°F)
Accuracy: See chart on PDF
Internal/External Humidity
Humidity Range: 0 to 100% RH
Humidity Resolution: 0.01% RH
Accuracy: See chart on PDF
Reading Rate: 1 second to 24 hours; 2 Hz, 4 Hz in fast mode
Start Modes: Immediate start, delayed start
Memory Capacity
OMYL-RH25: 100,000 readings
OMYL-RH25-4M: 4 million readings
Memory Wrap Around: Yes (software configurable)
Battery: 3V lithium battery [standard temperature range battery (included), optional high temperature range battery]; user replaceable
Battery Life (Standard Temperature Range Battery): 4 years at 1 minute reading rate, 230 days at 10 second reading rate, 25 days at 1 second reading rate
LED Functionality: Integrated status LED indicates data logging status, low battery or alarm condition
Alarms: Software programmable high/low thresholds
Computer Interface: USB (interface cable included)
Software: XP SP3/Vista/7 and 8 (32- and 64-bit)
Operating Environment: -30 to 70°C (-22 to 158°F) with standard lithium battery; -40 to 90°C (-40 to 194°F) with optional high temperature lithium battery
Dimensions: 30 H x 50 mm dia (1.18 x 1.97')
Weight: 70 g (2.5 oz)
Enclosure: Robust, shock-proof POM, IP65
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 5ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getContent, 19ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
fr-CA
fr
Enregistrer la configuration