DRSP-I-DC
DC Current Signal Splitters

Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | C$888.31 |
5-9 | C$843.89 |
10-24 | C$826.13 |
25-49 | C$790.60 |
50-99 | C$772.83 |
100+ | C$755.06 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
CMRR | 120 dB minimum |
Current Measurement Range | 4 to 20 mA |
Electrical Connection | Screw Terminal |
Electrical Output | 4 to 20 mA |
Enclosure Ratings | IP40 |
Height | 117 mm |
Impedance Input | 50 Ω typical |
Input Range Note | Input Loop Power Supply:15 Vdc ±10%, regulated, 25 mA;May be selectively wired for sinking or sourcing mA input;Loop Status LEDs: Variable brightness LEDs indicate I/O loop level and status; One for input, one for each output. |
Input Type | Current |
Isolation | Isolation (Full 4-Way Isolation):input 1, output 1, output 2, power;1200 VRMS minimum |
LED Indicators | Loop Status LEDs: Variable brightness LEDs indicate I/O loop level and status; One for input, one for each output |
Length | 122 mm |
Linearity | Output Linearity: ±0.1% of span |
Mounting | DIN Rail 35 mm Standard |
Number of Inputs | 1 |
Operating Temperature, Max | 60 °C |
Operating Temperature, Min | -10 °C |
Output Detail | (Output 1 and Output 2): 4 to 20 mA;20V compliance, 1000 Ω at 20 mA Output Zero and Span: Multi-turn zero and span potentiometers for each output channel to compensate for load and lead variations; ±15% of span adjustment range typical Output Loop Power Supplies: One for each output channel; 20 Vdc nominal, regulated, 25 mA may be selectively wired for sinking or sourcing mA output. Output Functional Test: Front buttons set each output to test level when pressed; Each test level potentiometer adjustable 0 to 100% of span |
Output Ripple | Output Ripple and Noise: <10 mVRMS |
Output Signal | Current |
Output Value | Splitter |
Response Time | 70 ms typical |
Stability | ±0.04% of span per °C |
Supply Power Note | 9 to 30 Vdc or10 to 32 Vac 50/60 Hz,6 W maximum |
Supply Power Type | DC |
Supply Voltage | 9 to 30 Vdc |
Width | 45 mm |
Wire Gauge | 14 AWG |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
Windsor Township from
Municipal Electrician
Always encounter a helpful staff and a fair amount of stock
Date published: 2021-02-09