Welcome to our new website, found an issue or bug? Please report it here
Back To Top
Load More Items from this family (28) ...
DIN Rail Signal Conditioners
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Added to Your Shopping Cart

The TXDIN70 series provide two channel transmitters or isolators with 4-20 or 0-20 mA output. Programmable input types with TXDIN70-DISPLAY accessory (sold separately)
Product Number | Input Type | Supply Voltage | Voltage Measurement Range |
---|---|---|---|
|
Thermocouple, RTD, Voltage
|
100 to 240 Vac, 24 Vdc
|
0 to 20 mV, 0 to 60 mV, 0 to 100 mV, 0 to 1V, 0.2 to 1V
|
|
Thermocouple, RTD, Voltage
|
24 Vdc
|
0 to 20 mV, 0 to 60 mV, 0 to 100 mV, 0 to 1V, 0.2 to 1V
|

The DMD4059 Series converts wheatstone strain bridge sensors, pressure transducers, or load cell signals into process current or voltage. Offered with AC or DC Power.
Product Number | Input Type |
---|---|
|
Low Voltage
|
|
Voltage
|

The LDX-D is a DIN rail mount AC LVDT transducer that operates on 10-30Vdc power with selectable process outputs. Adjustable signal polarity, span, and offset.
Product Number | Input Type |
---|---|
|
AC Voltage
|

The DRSL-SP1 is a repeater/splitter that isolates and converts 1 current input to 2 current outputs. Slim housing, high accuracy (0.05%), no setup needed.
Product Number | Input Type |
---|---|
|
Current
|

The DRST-FR converts frequency/pulse inputs to a 4-20mA or 0-10V DC output. PNP/NPN output, relay output. Universal power supply. Configurable with TXUN-KIT device.
Product Number | Input Type |
---|---|
|
Frequency
|

The DRST-CM is a programming display for DRST-AC, DRST-DC, DRST-UN & DRST-UR. Supports Modbus over RS-485. Monitors process value on built in display.
Product Number | Display Type |
---|---|
|
N/A
|

The DRSL-RTD is either isolated or non-isolated with 2, 3, or 4-wire Pt100 RTD input. Pre-calibrated temp ranges selectable via DIP switch. Slim housing, high accuracy.
Product Number | Accuracy |
---|---|
|
± 0.05 %
|
|
± 0.1 %
|

The DRST-AC measures AC current or voltage signals and outputs passive or active current signals. UL and c-UL approved. Universal power. Programmer required.
Product Number | Input Type |
---|---|
|
AC Current , Voltage
|

CCT DIN rail conditioners that accept various input signals, such as voltage and current, frequency, temperature (TC and RTD), and provide 0/4 to 20 mA, or 0 to 10 Vdc.
Product Number | Current Measurement Range | Frequency Measurement Range | Input Type | Supply Voltage | Temperature Measurement Range | Voltage Measurement Range |
---|---|---|---|---|---|---|
|
0 to 50 mA dc
|
N/A
|
Voltage, Current
|
110 Vac
|
N/A
|
18 Vdc Max
|
|
0 to 5 mA, 0 to 50 mA
|
N/A
|
Current
|
110 Vac
|
N/A
|
N/A
|
|
N/A
|
N/A
|
Voltage
|
110 Vac
|
N/A
|
0 to 0.1 Vdc, 0 to 1 Vdc, 0 to 10 Vdc, 0 to 100 Vdc, 0 to 650 Vdc
|
|
N/A
|
N/A
|
Voltage
|
110 Vac
|
N/A
|
0 to 2 Vdc
|
|
N/A
|
N/A
|
AC Voltage
|
110 Vac
|
N/A
|
0 to 1 Vac
|

The DRSL-RTD-LP is a 2, 3, or 4-wire PT100 RTD input conditioner. Output loop powered with high accuracy and slim housing. Pre-calibrated temp range DIP switch selected.
Product Number | Input Type |
---|---|
|
RTD
|

DRA-ACT-S Series DIN Rail Conditioners are self powered AC Current/Voltage input and convert to either 0-1mA or 0-20mA output. Self powered design.
Product Number | Electrical Output | Power Consumption | Voltage Measurement Range |
---|---|---|---|
|
4 to 20 mA
|
0.6 VA @ 5 A
|
N/A
|
|
0 to 1 mA
|
0.9 VA @ 300 Vac
|
0 to 300 Vac
|
|
0 to 20 mA
|
0.9 VA @ 300 Vac
|
0 to 150 Vac
|
|
0 to 20 mA
|
0.9 VA @ 300 Vac
|
0 to 300 Vac
|

The DRST-DC measures unipolar or bipolar DC current and voltage signals. Passive/active current buffered output voltage. Additional programmer required.
Product Number | Input Type |
---|---|
|
Current, Voltage, Potentiometer
|

The DRST-BG is a load cell & strain gage amplifier that converts mV to current or voltage. Front panel programmable LED display | Calibration of input span, external taring.
Product Number | Input Type |
---|---|
|
Voltage
|

The DRSL-DC4 Signal Conditioners convert bipolar process voltage and current signals to unipolar signals. DIP switch selectable range, slim housing, high accuracy (0.05%).
Product Number | Input Type |
---|---|
|
Voltage, Current
|

TXDIN101 has thermocouple, RTD, and mV input with 4-20mA output. LED display, configuration TX69-CABLE sold separately required to program via PC.
Product Number | Input Type |
---|---|
|
Thermocouple, RTD, Voltage
|

The DRSP-I Series are DC current splitters that take one 4-20mA input to two 4-20mA outputs w/ AC or DC power. Zero and span adjustments for each output, status LEDs.

The DRSL-SP2 is a repeater/splitter that isolates and converts 1 process input to 2 process outputs. DIP switch selectable ranges. Slim housing, high accuracy (0.05%)
Product Number | Input Type |
---|---|
|
Voltage, Current
|

The DRSL-U is a universal input conditioner that accepts thermocouple, RTD, resistance, potentiometer, voltage or current input. Configured w/ DRSL-DISPLAY programmer.
Product Number | Input Type |
---|---|
|
Thermocouple, RTD, Resistance, Potentiometer, Current, Voltage
|

The DIN Rail DMD4380 Series converts, amplifies, filters and optically isolates mA or V input signals to process current or voltage outputs. Loop powered w/ 1200V isolation.
Product Number | Input Type |
---|---|
|
Voltage, Current
|
|
Current, Low Voltage
|

DRA-ACT-4 Series DIN Rail Conditioners take a 4 wire AC Current/Voltage input and converts to 4-20mA output. AC Powered 115V or optional 230 V power.
Product Number | Power Consumption | Supply Voltage |
---|---|---|
|
0.3 VA
|
115 Vac
|
|
1.4 VA
|
115 Vac
|
|
1.4 VA
|
220 Vac
|
DIN Rail Signal Conditioners