Welcome to our new website, found an issue or bug? Please report it here
CCT-55-I
Economical DIN Rail Signal Conditioners

Choose a Variant
Input Type
Current Measurement Range
Voltage Measurement Range
Temperature Measurement Range
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | C$517.96 |
5-9 | C$492.06 |
10-24 | C$481.70 |
25-49 | C$460.98 |
50-99 | C$450.63 |
100+ | C$440.27 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Product Specs
<< See all Product ModelsBrand |
![]() |
Accuracy | ± 0.2 % |
Approvals | CE, UL |
Approvals Note | Enclosure: UL 94 V-1, Terminal Housing: UL 94-2 |
Bandwidth | 1.5 Hz (-3 dB) |
Current Measurement Range | 0 to 5 mA, 0 to 50 mA |
Enclosure Ratings | IP20, IP40 |
Frequency Measurement Range | N/A |
Height | 75 mm |
Input Type | Current |
Isolation | 2000 Vrms |
Length | 110 mm |
Materials | Polycarbonate, RAL 7032 |
Mounting | DIN Rail 46277 and EN 50022 |
Number of Inputs | 1 |
Operating Temperature, Max | 60 °C |
Operating Temperature, Min | -10 °C |
Output Detail | 15 Vdc @ 5 mA source or 100 mA sink with 24 Vdc external supply Output Ranges: 1 pulse/hr to 10,000 pulses/sec full scale; jumper select and poteniometer adjustment |
Output Ripple | ≤0.5% |
Output Signal | Current, Voltage |
Output Value | Process |
Power Consumption | max 1.5 VA |
Pulse Rates | 50% or fixed 100 ms |
Response Time | ≤250 ms |
Serial Number | Break Protection: Jumper selectable, upscale (>20 mA) or downscale (<4 mA) |
Storage Temperature, Max | 80 °C |
Storage Temperature, Min | -30 °C |
Supply Power Note | 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies) |
Supply Power Type | AC |
Supply Voltage | 110 Vac |
Temperature Coefficient | ≤0.015%/°C |
Temperature Measurement Range | N/A |
Voltage Measurement Range | N/A |
Voltage Output Range | 15 Vdc |
Weight | 270 g |
Width | 45 mm |
Wire Gauge | 14 AWG |
See All Specs |
PDFs & Manuals
Show Ratings & Reviews
Rated 5 out of
5
by
Russell from
turns Pt thermometer into 0-10V signal
The low level output of a Pt thermometer will result in a staircase graph when used with an analog to digital converter with low resolution. Amplifying the output smooth's the graph, and increases the resolution very nicely.
Date published: 2016-08-23
Rated 5 out of
5
by
nafm from
easy to calibrate to my application
Replaced a unit that served well for almost 15 years..
Date published: 2017-09-03
Rated 5 out of
5
by
Purchasing Agent from
As desribed
Product arrived in a timely manner and as decribed
Date published: 2023-07-27