Welcome to our new website, found an issue or bug? Please report it here

LDX-4-LVDT-Sig-Cond
Signal Conditioning Amplifier and Power Supply for AC LVDT's
LDX-4-LVDT-Sig-Cond
From
C$
1,350.56

Product Overview
- Approvals CE
- Bandwidth 500 kHz
- Electrical Connection Internal Terminal Block
- Electrical Output +5V, ±10V, 20 mA
- Height 65 mm
- Input Electrical Connection 5-pin circular DIN
- Input Noise 20 mV p-p @ 100 kHz
- Input Type Voltage
- Load Resistance 1 kΩ
- Non-Linearity <0.1% BSL
- Operating Temperature, Max 60 °C
- Operating Temperature, Min 0 °C
- Output Detail Offset Range: 0 to 100%
- Protection Input Protection: Overvoltage, reverse connection
- Sensitivity Transducer : 45 to 450 mV/V
- Sensor Excitation 3 Vrms @ 5 kHz
- Supply Power Note Voltage Output: 140 mA max with 10 Vdc supply voltage; 60 mA max with 30 Vdc supply voltage Current Output: 180 mA max with 10 Vdc supply voltage; 70 mA max with 30 Vdc supply voltage
- Supply Power Type DC
- Supply Voltage 10 to 30 Vdc
- Temperature Coefficient Gain:<200 ppm/°C;Output:<200 ppm/°C
- Weight 300 g
- Width 40 mm
The LDX-4 is a dc powered signal conditioning amplifier and power supply for ac LVDT's. Its compact, rugged case can withstand industrial installations and protect laboratory grade electronics. Complete zero and span adjustments allow the LDX-4 to be used with any LVDT with an output between 45 and 450 mV/V full scale. Selectable outputs of ± 5 V or ± 10 V interface with recorders, displays, and other instruments. Also, when using the ± 5 V output range, a second 0 - 20 mA signal is available for retransmitting the signal over long distances.
SPECIFICATIONS
Supply Voltage: 10 to 30 Vdc
Supply Current (voltage output): 140 mA max. with 10 Vdc supply voltage; 60 mA max. with 30 Vdc supply voltage
Supply Current (current output): 180 mA max. with 10 Vdc supply voltage; 70 mA max. with 30 Vdc supply voltage
Noise on Power Supply (typical): 20 mV pp @ 100 kHz
Input Protection: Over voltage, reverse connection
Transducer Energization: 3V rms @ 5 kHz
Transducer Range:45 to 450 mV/V full scale
Output Voltage (selectable): ± 5 Vdc or ± 10 Vdc full scale
Load Resistance: 1 kΩ minimum
Analog Output Current: + 20 mA full scale into 1500 Ω maximum (only with 5 V range selected)
Offset Range: 0 to 100%
Gain Temperature Coefficient: < 200 ppm/°C
Output Temperature Coefficient: < 200 ppm/°C
Output Noise: < 20 mV pp @ 10 to 100 kHz
Non-Linearity: < 0.1% BSL
Temperature Range: 0 to 60°C (-18 to 140°F)
Weight (approx.): 300g (11 oz)
Dimensions: 40 H x 65 W x 120 mm L (157 x 256 x 4.72")
SPECIFICATIONS
Supply Voltage: 10 to 30 Vdc
Supply Current (voltage output): 140 mA max. with 10 Vdc supply voltage; 60 mA max. with 30 Vdc supply voltage
Supply Current (current output): 180 mA max. with 10 Vdc supply voltage; 70 mA max. with 30 Vdc supply voltage
Noise on Power Supply (typical): 20 mV pp @ 100 kHz
Input Protection: Over voltage, reverse connection
Transducer Energization: 3V rms @ 5 kHz
Transducer Range:45 to 450 mV/V full scale
Output Voltage (selectable): ± 5 Vdc or ± 10 Vdc full scale
Load Resistance: 1 kΩ minimum
Analog Output Current: + 20 mA full scale into 1500 Ω maximum (only with 5 V range selected)
Offset Range: 0 to 100%
Gain Temperature Coefficient: < 200 ppm/°C
Output Temperature Coefficient: < 200 ppm/°C
Output Noise: < 20 mV pp @ 10 to 100 kHz
Non-Linearity: < 0.1% BSL
Temperature Range: 0 to 60°C (-18 to 140°F)
Weight (approx.): 300g (11 oz)
Dimensions: 40 H x 65 W x 120 mm L (157 x 256 x 4.72")
PDFs & Manuals