<< Voir toutes les modèles de produits
Brand
Accuracy ± 0.2 %
Approvals CE, UL
Approvals Note Enclosure: UL 94 V-1, Terminal Housing: UL 94-2
Bandwidth 1.5 Hz (-3 dB)
Current Measurement Range N/A
Electrical Output 4 to 20 mA
Enclosure Ratings IP20, IP40
Frequency Measurement Range N/A
Height 75 mm
Impedance Input 1 MΩ
Input Type Voltage
Isolation 2000 Vrms
Length 110 mm
Materials Polycarbonate, RAL 7032
Mounting DIN Rail 46277 and EN 50022
Number of Inputs 1
Operating Temperature, Max 60 °C
Operating Temperature, Min -10 °C
Output Detail 4 to 20 mA and 0 to 10 Vdc standard; 0 to 20 mA via jumper select
Output Ripple ≤0.5%
Output Signal Current, Voltage
Output Value Process
Overvoltage 1000 Vdc/750 vac
Power Consumption max 1.5 VA
Response Time ≤250 ms
Serial Number Break Protection: Jumper selectable, upscale (>20 mA) or downscale (<4 mA)
Storage Temperature, Max 80 °C
Storage Temperature, Min -30 °C
Supply Power Note 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies)
Supply Power Type AC
Supply Voltage 110 Vac
Temperature Coefficient ≤0.015%/°C
Temperature Measurement Range N/A
Voltage Measurement Range 0 to 2 Vdc
Voltage Output Range 0 to 10 Vdc
Weight 270 g
Width 45 mm
Wire Gauge 14 AWG
Voir toutes Spécs Montrer moins
Economical DIN Rail Signal Conditioners CCT-01-0/2V CCT-01-0/2V
Rated 5 out of 5 by from turns Pt thermometer into 0-10V signal The low level output of a Pt thermometer will result in a staircase graph when used with an analog to digital converter with low resolution. Amplifying the output smooth's the graph, and increases the resolution very nicely.
Date published: 2016-08-23
Rated 5 out of 5 by from easy to calibrate to my application Replaced a unit that served well for almost 15 years..
Date published: 2017-09-03
Rated 5 out of 5 by from As desribed Product arrived in a timely manner and as decribed
Date published: 2023-07-27
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_CCT-01-0-2V, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration