The TXDIN70 series provide two channel transmitters or isolators with 4-20 or 0-20 mA output. Programmable input types with TXDIN70-DISPLAY accessory (sold separately)
Numéro de produit | Input Type | Supply Voltage | Voltage Measurement Range |
---|---|---|---|
|
Thermocouple, RTD, Voltage
|
100 to 240 Vac, 24 Vdc
|
0 to 20 mV, 0 to 60 mV, 0 to 100 mV, 0 to 1V, 0.2 to 1V
|
|
Thermocouple, RTD, Voltage
|
24 Vdc
|
0 to 20 mV, 0 to 60 mV, 0 to 100 mV, 0 to 1V, 0.2 to 1V
|

The DMD4059 Series converts wheatstone strain bridge sensors, pressure transducers, or load cell signals into process current or voltage. Offered with AC or DC Power.
Numéro de produit | Input Type |
---|---|
|
Low Voltage
|
|
Voltage
|

The LDX-D is a DIN rail mount AC LVDT transducer that operates on 10-30Vdc power with selectable process outputs. Adjustable signal polarity, span, and offset.
Numéro de produit | Input Type |
---|---|
|
AC Voltage
|

The DRSL-SP1 is a repeater/splitter that isolates and converts 1 current input to 2 current outputs. Slim housing, high accuracy (0.05%), no setup needed.
Numéro de produit | Input Type |
---|---|
|
Current
|

The DRST-FR converts frequency/pulse inputs to a 4-20mA or 0-10V DC output. PNP/NPN output, relay output. Universal power supply. Configurable with TXUN-KIT device.
Numéro de produit | Input Type |
---|---|
|
Frequency
|

The DRSL-RTD is either isolated or non-isolated with 2, 3, or 4-wire Pt100 RTD input. Pre-calibrated temp ranges selectable via DIP switch. Slim housing, high accuracy.
Numéro de produit | Accuracy |
---|---|
|
± 0.1 %
|
|
± 0.05 %
|

The DRST-CM is a programming display for DRST-AC, DRST-DC, DRST-UN & DRST-UR. Supports Modbus over RS-485. Monitors process value on built in display.
Numéro de produit | Display Type |
---|---|
|
N/A
|

The DRST-AC measures AC current or voltage signals and outputs passive or active current signals. UL and c-UL approved. Universal power. Programmer required.
Numéro de produit | Input Type |
---|---|
|
AC Current , Voltage
|

The DRSL-RTD-LP is a 2, 3, or 4-wire PT100 RTD input conditioner. Output loop powered with high accuracy and slim housing. Pre-calibrated temp range DIP switch selected.
Numéro de produit | Input Type |
---|---|
|
RTD
|

The DRSL-U is a universal input conditioner that accepts thermocouple, RTD, resistance, potentiometer, voltage or current input. Configured w/ DRSL-DISPLAY programmer.
Numéro de produit | Input Type |
---|---|
|
Thermocouple, RTD, Resistance, Potentiometer, Current, Voltage
|

DRA-ACT-S Series DIN Rail Conditioners are self powered AC Current/Voltage input and convert to either 0-1mA or 0-20mA output. Self powered design.
Numéro de produit | Electrical Output | Power Consumption | Voltage Measurement Range |
---|---|---|---|
|
4 to 20 mA
|
0.6 VA @ 5 A
|
N/A
|
|
0 to 1 mA
|
0.9 VA @ 300 Vac
|
0 to 300 Vac
|
|
0 to 20 mA
|
0.9 VA @ 300 Vac
|
0 to 150 Vac
|
|
0 to 20 mA
|
0.9 VA @ 300 Vac
|
0 to 300 Vac
|

The DRSP-I Series are DC current splitters that take one 4-20mA input to two 4-20mA outputs w/ AC or DC power. Zero and span adjustments for each output, status LEDs.

The DRST-DC measures unipolar or bipolar DC current and voltage signals. Passive/active current buffered output voltage. Additional programmer required.
Numéro de produit | Input Type |
---|---|
|
Current, Voltage, Potentiometer
|

The DRG-SC Series Conditioners have models with TC, RTD, Pot, Freq., AC/DC Voltage/Current, Strain/Bridge inputs and field configurable outputs from 0-5V, 0-10V, 0-20mA.
Numéro de produit | Input Type |
---|---|
|
RTD
|
|
Voltage, Current (bipolar)
|

CCT DIN rail conditioners that accept various input signals, such as voltage and current, frequency, temperature (TC and RTD), and provide 0/4 to 20 mA, or 0 to 10 Vdc.
Numéro de produit | Current Measurement Range | Frequency Measurement Range | Input Type | Supply Voltage | Temperature Measurement Range | Voltage Measurement Range |
---|---|---|---|---|---|---|
|
0 to 50 mA dc
|
N/A
|
Voltage, Current
|
110 Vac
|
N/A
|
18 Vdc Max
|
|
0 to 5 mA, 0 to 50 mA
|
N/A
|
Current
|
110 Vac
|
N/A
|
N/A
|
|
N/A
|
N/A
|
Voltage
|
110 Vac
|
N/A
|
0 to 0.1 Vdc, 0 to 1 Vdc, 0 to 10 Vdc, 0 to 100 Vdc, 0 to 650 Vdc
|
|
N/A
|
N/A
|
Voltage
|
110 Vac
|
N/A
|
0 to 2 Vdc
|
|
N/A
|
N/A
|
AC Voltage
|
110 Vac
|
N/A
|
0 to 1 Vac
|

The DRSL-SP2 is a repeater/splitter that isolates and converts 1 process input to 2 process outputs. DIP switch selectable ranges. Slim housing, high accuracy (0.05%)
Numéro de produit | Input Type |
---|---|
|
Voltage, Current
|

The DRST-BG is a load cell & strain gage amplifier that converts mV to current or voltage. Front panel programmable LED display | Calibration of input span, external taring.
Numéro de produit | Input Type |
---|---|
|
Voltage
|

The DRSL-DC4 Signal Conditioners convert bipolar process voltage and current signals to unipolar signals. DIP switch selectable range, slim housing, high accuracy (0.05%).
Numéro de produit | Input Type |
---|---|
|
Voltage, Current
|

TXDIN101 has thermocouple, RTD, and mV input with 4-20mA output. LED display, configuration TX69-CABLE sold separately required to program via PC.
Numéro de produit | Input Type |
---|---|
|
Thermocouple, RTD, Voltage
|

The DIN Rail DMD4380 Series converts, amplifies, filters and optically isolates mA or V input signals to process current or voltage outputs. Loop powered w/ 1200V isolation.
Numéro de produit | Input Type |
---|---|
|
Voltage, Current
|
|
Current, Low Voltage
|
Conditionneurs de signal à montage sur rail DIN
Les conditionneurs de signaux sur rail DIN convertissent les signaux d'entrée provenant de ther...
[+]