Skip to search Skip to main content Skip to navigation

1-800-663-4209 | Vos commentaires sont importants, répondez à un sondage rapide commentaires sur le site web

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

CCT-55-V

Economical DIN Rail Signal Conditioners

C$528.84

Article# CCT-55-V

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$528.84
5-9 C$502.40
10-24 C$491.82
25-49 C$470.67
50-99 C$460.09
100+ C$449.51

En stock

Délai de livraison (si pas en stock): 6 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Accuracy ± 0.2 %
Approvals CE, UL
Approvals Note Enclosure: UL 94 V-1, Terminal Housing: UL 94-2
Bandwidth 1.5 Hz (-3 dB)
Current Measurement Range N/A
Enclosure Ratings IP20, IP40
Frequency Measurement Range N/A
Height 75 mm
Input Type Voltage
Isolation 2000 Vrms
Length 110 mm
Materials Polycarbonate, RAL 7032
Mounting DIN Rail 46277 and EN 50022
Number of Inputs 1
Operating Temperature, Max 60 °C
Operating Temperature, Min -10 °C
Output Detail 15 Vdc @ 5 mA source or 100 mA sink with 24 Vdc external supply Output Ranges: 1 pulse/hr to 10,000 pulses/sec full scale; jumper select and poteniometer adjustment
Output Ripple ≤0.5%
Output Signal Voltage
Output Value Process
Power Consumption max 1.5 VA
Pulse Rates 50% or fixed 100 ms
Response Time ≤250 ms
Serial Number Break Protection: Jumper selectable, upscale (>20 mA) or downscale (<4 mA)
Storage Temperature, Max 80 °C
Storage Temperature, Min -30 °C
Supply Power Note 110 Vac (standard); 220 Vac or 24 Vdc (optional) (±10% tolerance on all power supplies)
Supply Power Type AC
Supply Voltage 110 Vac
Temperature Coefficient ≤0.015%/°C
Temperature Measurement Range N/A
Voltage Measurement Range 0 to 0.1 Vdc, 0 to 1 Vdc, 0 to 10 Vdc, 0 to 100 Vdc, 0 to 650 Vdc
Voltage Output Range 15 Vdc
Weight 270 g
Width 45 mm
Wire Gauge 14 AWG
Voir toutes Spécs Montrer moins
Economical DIN Rail Signal Conditioners CCT-55-V CCT-55-V
Rated 5 out of 5 by from turns Pt thermometer into 0-10V signal The low level output of a Pt thermometer will result in a staircase graph when used with an analog to digital converter with low resolution. Amplifying the output smooth's the graph, and increases the resolution very nicely.
Date published: 2016-08-23
Rated 5 out of 5 by from easy to calibrate to my application Replaced a unit that served well for almost 15 years..
Date published: 2017-09-03
Rated 5 out of 5 by from As desribed Product arrived in a timely manner and as decribed
Date published: 2023-07-27
  • y_2025, m_4, d_18, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_CA, sid_CCT-55-V, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration