L'aperçu du produit
- Accuracy ±8 µA
- Approvals CE, UL, RoHS
- Bandwidth 100 Hz
- Calibration Temperature, Max 28 °C
- Calibration Temperature, Min 20 °C
- Conversion Rate 1:1
- Current Measurement Range 4 to 20 mA
- Electrical Output 24 mA
- EMC Immunity Note Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <±1% of span
- EMC Standard NAMUR NE 21
- Enclosure Ratings IP20
- Height 113 mm
- Input Range Note Signal Range (Input to Output):3.8 to 20.5 mA;Signal Conversion: 1:1; Functional Range: 3.5 to 23 mA ;(NAMUR NE43 compliant);Available 2-Wire Transmitter (Tx) ;Supply: 3.5 to 32.5V
- Input Type Current
- Installation Pollution degree 2 and measurement/overvoltage category II
- Isolation Isolation Voltage (Test): 2.5 kVac ;Isolation Voltage (Working):300 Vac
- Length 115 mm
- Mounting DIN Rail 35 mm Standard, EN 60715
- Noise Calibration >60 dB
- Operating Temperature, Max 70 °C
- Operating Temperature, Min -25 °C
- Output Detail Output Loop Current Limitation:24 mA typical Output Overload: 50 mA max
- Output Signal Current
- Output Value Process
- Power Consumption 50 mW
- Relative Humidity 0 to 95% RH (non-condensing)
- Response Time < 5 ms
- Response Time Note Response Time (0 to 90%, 100 to 10%): <5 ms
- Screw Terminal Torque 0.5 Nm
- Storage Temperature, Max 85 °C
- Storage Temperature, Min -40 °C
- Supply Power Type DC
- Supply Voltage 6 to 35 Vdc
- Temperature Coefficient ≤±0.02 µA [(T-25°C) x Vsupply]
- Temperature Coefficient Note Temperature Coefficient (>25°C):≤±0.02 µA [(T-25°C) x Vsupply] Temperature Coefficient (<25°C):≤±0.07 µA [(T-25°C) x Vsupply]
- Voltage Loss Input to Output: 2.5 V
- Weight 70 g
- Width 6.1 mm
- Wire Gauge 26 to 12 AWG
The DRSL-LPO Series DIN rail 2-wire transmitter isolators provide a competitive choice in terms of both price and technology for galvanic isolation of current signals to SCADA systems or PLC equipment. These units provide isolation and 1:1 conversion of standard current signals and are powered by the host (output) current signal loop. Input transmitter (Tx) power supply of 3.5 to 32.5V is provided.
The DRSL-LPO series offers isolation between input and output, provides surge suppression and protects control systems from transients and noise. These units also eliminate ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. These isolators operates over a wide temperature range from -25 to 70°C (-13 to 158°F).
SPECIFICATIONS
NUMBER OF CHANNELS
DRSL-LPO-1: 1
DRSL-LPO-2: 2
CURRENT INPUT
Signal Range (Input to Output): 3.8 to 20.5 mA
Signal Conversion: 1:1
Functional Range: 3.5 to 23 mA (NAMUR NE43 compliant)
Available 2-Wire Transmitter (Tx) Supply: 3.5 to 32.5V
CURRENT OUTPUT
Output Loop Current Limitation: 24 mA typical
Output Overload: 50 mA max
GENERAL
Supply Voltage: 6 to 35 Vdc
Internal Consumption: 50 mW per channel
Voltage Drop (Input to Output): 2.5V typical
Isolation Voltage (Test): 2.5 kVac
Isolation Voltage (Working): 300 Vac
Signal/Noise Ratio: >60 dB
Cut-Off Frequency (3 dB): 100 Hz
Response Time (0 to 90%, 100 to 10%): <5 ms
Absolute Accuracy (at 25°C): ≠¤± 8 µA
Temperature Coefficient (>25°C): ≠¤± 0.02 µA [(T-25°C) x Vsupply]
Temperature Coefficient (<25°C): ≠¤± 0.07 µA [(T-25°C) x Vsupply]
EMC Immunity Influence: <± 0.5% of span (4 to 20 mA)
Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <± 1% of span
ENVIRONMENTAL
Operating Temperature: -25 to 70°C (-13 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Calibration Temperature: 20 to 28°C (68 to 82°F)
Relative Humidity: 0 to 95% RH non-condensing
Protection Degree: IP20
Installation Area: Pollution degree 2 and measurement/overvoltage category II
MECHANICAL
Dimensions: 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Weight: 70 g (0.15 lb) approx
DIN Rail Type: DIN EN 60715 - 35 mm
Wire Size: 0.13 x 2.5 mm²/ AWG 26 to 12 stranded wire
Screw Terminal Torque: 0.5 Nm
The DRSL-LPO series offers isolation between input and output, provides surge suppression and protects control systems from transients and noise. These units also eliminate ground loops and can be used for measuring floating signals. Low power consumption facilitates DIN rail mounting without the need for any air gap. Measurement ranges are factory calibrated. These isolators operates over a wide temperature range from -25 to 70°C (-13 to 158°F).
SPECIFICATIONS
NUMBER OF CHANNELS
DRSL-LPO-1: 1
DRSL-LPO-2: 2
CURRENT INPUT
Signal Range (Input to Output): 3.8 to 20.5 mA
Signal Conversion: 1:1
Functional Range: 3.5 to 23 mA (NAMUR NE43 compliant)
Available 2-Wire Transmitter (Tx) Supply: 3.5 to 32.5V
CURRENT OUTPUT
Output Loop Current Limitation: 24 mA typical
Output Overload: 50 mA max
GENERAL
Supply Voltage: 6 to 35 Vdc
Internal Consumption: 50 mW per channel
Voltage Drop (Input to Output): 2.5V typical
Isolation Voltage (Test): 2.5 kVac
Isolation Voltage (Working): 300 Vac
Signal/Noise Ratio: >60 dB
Cut-Off Frequency (3 dB): 100 Hz
Response Time (0 to 90%, 100 to 10%): <5 ms
Absolute Accuracy (at 25°C): ≠¤± 8 µA
Temperature Coefficient (>25°C): ≠¤± 0.02 µA [(T-25°C) x Vsupply]
Temperature Coefficient (<25°C): ≠¤± 0.07 µA [(T-25°C) x Vsupply]
EMC Immunity Influence: <± 0.5% of span (4 to 20 mA)
Extended EMC Immunity NAMUR NE 21, A Criterion, Burst: <± 1% of span
ENVIRONMENTAL
Operating Temperature: -25 to 70°C (-13 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Calibration Temperature: 20 to 28°C (68 to 82°F)
Relative Humidity: 0 to 95% RH non-condensing
Protection Degree: IP20
Installation Area: Pollution degree 2 and measurement/overvoltage category II
MECHANICAL
Dimensions: 113 H x 6.1 W x 115 mm D (4.4 x 0.24 x 4.5")
Weight: 70 g (0.15 lb) approx
DIN Rail Type: DIN EN 60715 - 35 mm
Wire Size: 0.13 x 2.5 mm²/ AWG 26 to 12 stranded wire
Screw Terminal Torque: 0.5 Nm