Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

DRSL-RTD

RTD Input DIN Rail Signal Conditioners

C$201.77

Article# DRSL-RTD

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$201.77
5-9 C$191.68
10-24 C$187.65
25-49 C$179.58
50-99 C$175.54
100+ C$171.50

En stock

Délai de livraison (si pas en stock): 24 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Accuracy ± 0.1 %
Accuracy Note Better than 0.2°C or ±0.1% of selected range
Approvals CE, UL, RoHS
Calibration Temperature, Max 28 °C
Calibration Temperature, Min 20 °C
EMC Immunity Note NAMUR NE 21, A Criterion, Burst: <±1% of span (span = selected input range)
EMC Standard NAMUR NE 21
Electrical Output 4 to 20 mA
Enclosure Ratings IP20
Height 113 mm
Input Range Note Sensor Current, RTD: <150 µA;Sensor Cable Specifications: 50 Ωper wire or 50 nF;Effect of Sensor Cable Resistance (3 or 4-wire RTD): <0.002 Ω/Ω;Broken Sensor Detection: >800 Ω;Shorted Sensor Detection: <18 Ω
Input Type RTD
Installation Pollution degree 2 and measurement/overvoltage category II
Length 115 mm
Load Resistance Current Output : 21 mA/600Ω /12.6V max;Voltage Output:>10 kΩ min
Mounting DIN Rail 35 mm Standard, EN 60715
Noise Calibration >60 dB
Number of Inputs 1
Operating Temperature, Max 70 °C
Operating Temperature, Min -25 °C
Output Detail Current: Range Limits(NAMUR NE43 Out of Range):Below 3.8 mA or above 20.5 mA for 4 to 20 mA output; 0 mA or above 20.5 mA for 0 to 20 mA output Sensor Error Detection(Dip Switch Selectable for Enable or None): Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output Incorrect DIP-Switch Setting Identification: Below 3.5 mA or above 23 mA for 4 to 20 mA output; 0 mA or above 23 mA for 0 to 20 mA output Output Error Level: DIP switch selectable for upscale or downscale. Voltage: Range Limits (Out of Range):Range ±2.5% Sensor Error Detection (Dip Switch Selectable for Enableor None): 0V or selected range + 10% Incorrect DIP-Switch Setting Identification: 0V Output Error Level: DIP switch selectable for upscale or downscale
Output Signal Current, Voltage
Output Value Process
Power Consumption 0.7 W, Internal - 0.65 W
Relative Humidity 0 to 95% RH (non-condensing)
Response Time < 30 ms
Response Time Note Response Time (0 to 90%, 100 to 10%): <30 ms/300 ms (selectable, provides either fast response or signal dampening as needed)
Screw Terminal Torque 0.5 Nm
Stability Load Stability: ≤0.01% of span/100 Ω
Storage Temperature, Max 85 °C
Storage Temperature, Min -40 °C
Supply Power Note 16.8 to 31.2 Vdc via connectors
Supply Power Type DC
Supply Voltage 16.8 to 31.2 Vdc
Temperature Coefficient ≤±0.02°C/°C
Voltage Output Range 0 to 10 Vdc
Weight 70 g
Width 6.1 mm
Wire Gauge 26 to 13 AWG
Voir toutes Spécs Montrer moins
RTD Input DIN Rail Signal Conditioners DRSL-RTD DRSL-RTD
Rated 5 out of 5 by from Excellent accuracy I bought this to be used in a test lab where temperature accuracy is 0.1C and the DRSL has stood up to the expectation. Excellent accuracy, stability, form factor and ease of use.
Date published: 2019-05-14
  • y_2025, m_2, d_22, h_8