Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

DRST-BG-Load-Cell-Cond
DIN RAIL Signal Conditioner for Load Cells
Modèles en stock
- Load cell & Strain Gage Amplifier
- MV to Current/Voltage Conversion
- Front-Programmable/LED Display
- Relative Calibration of Input Span
DRST-BG-Load-Cell-Cond
Depuis
C$
753.28
Modèles en stock

L'aperçu du produit
- Approvals Note EMC 2014/30/EU EAC: TR-CU 020/2011
- Calibration Temperature, Max 28 °C
- Calibration Temperature, Min 20 °C
- Display Type LED
- Electrical Output 0 to 20 mA
- EMC Standard NAMUR NE 21
- Enclosure Ratings IP50
- Height 80.5 mm
- Length 84.5 mm
- Linearity Error < 0.1% of span
- Load Resistance 230 mA Max;Current Output : 600 Ω
- Mounting DIN Rail Mount
- Noise Calibration >60 dB
- Offset Max Offset: 70 %
- Operating Temperature, Max 60 °C
- Operating Temperature, Min -20 °C
- Output Value Process
- Power Consumption 7.2 W
- Power Dissipation 2.2 W
- Relative Humidity <95% RH
- Signal Dynamics Input 17 bit
- Signal Dynamics Output 16 bit
- Stability Load Stability: 0.01% of span/100 Ω
- Supply Power Type DC
- Update Rate 20 ms
- Weight 130 g
- Width 35.5 mm
Brand New DRST-BG MV Signal Transmitter converts bipolar mV signals from transducers supplied directly by the device to standard current/voltage signals.
Application
DRST-BG is suitable for load cell application as well as other applications such as tank filling and draining, weighing with a taring function, measurement of cable tensile force, level control, signal conversion/amplification.
Advanced Features
A multifunction user interface consisting of three push buttons and a 3-digit LED display for programming.
Technical Characteristics
• Front error LED.
• The analog input can be programmed for voltage in the range -40 to 100 m Vdc.
• The digital signal can be selected as either NPN or PNP. Taring can either be by way of the digital input or from the front interface.
• The analog output can be programmed to current in the range 0 to 20 mA or voltage in the range • Short circuit protected transducer supply which can be programmed to 5 to 13 Vdc from the front.
• Sense input (with transducer supply used) for compensation for cable resistance to the transducer.
• Mounting for a standard 11-pole socket which can be adapted for DIN rail or plate.
Specifications
Environmental Conditions
Operating Temperature: -20 to 60°C
Calibration Temperature: 20 to 28°C
Relative Humidity: < 95% RH (non-cond.)
Protection Degree: IP50
Mechanical Specifications
Dimensions (HxWxD): 80.5 x 35.5 x 84.5 mm (D is without pins)
Weight Approx: 130 g
Common Specifications
Supply Voltage: 19.2 to 28.8 Vdc
Max. Required Power: 7.2 W
Internal Power Dissipation: 2.2 W
Response Time (Programmable): 0.06 to 999 s
Signal/Noise Ratio: Min. 60 dB
Updating Time: 20 ms
Signal Dynamics, Input: 17 bit
Signal Dynamics, Output: 16 bit
Effect of Supply Voltage Change: < ± 0.002% of span/%V
Temperature Coefficient: < ± 0.01% of span/°C
Linearity Error: < 0.1% of span
Auxiliary Voltage: Transducer
Supply: 5 to 13 Vdc
Load (Max.): 230 mA
EMC Immunity Influence: < ± 0.5% of span
Input Specifications
Common Input Specifications
Max. Offset: 70% of selec. max. value
Voltage input
Measurement Range: -40 to 100 mV
Min. Measurement Range (Span): 10 mV
Input Resistance: > 10 MO
Overrange: 0 to 999% of selected measurement range
NPN, Digital Input: Pull up 24 Vdc / 6.9 mA
PNP, Digital Input: Pull down 0 Vdc/6.9 mA
Trig Level Low, NPN/PNP: < 6 Vdc
Trig Level High, NPN/PNP: > 10.5 Vdc
Pulse Length: > 30 ms
Output Specifications
Current Output
Signal Range: 0 to 20 mA
Min. Signal Range: 5 mA
Load (@ Current Output): = 600 Ω
Load Stability:= 0.01% of span/100 Ω
Current Limit: < 23 mA
Voltage Output Through Internal
shunt: See manual for details
Of Span: = of the presently selected range
Observed Authority Requirements
EMC 2014/30/EU
EAC: TR-CU 020/2011
PDF et manuels
Afficher les notes et les avis
The DRST-BG says that is it capable of 10V output with JP2 ON (connecting the 500ohm) and J2 OFF. It looks like J1 and J2 are internal. Is this true. Do we need to physically open the box and manually change the jumpers in order to get 10V output?
Thank you for your question. We will require more information to help on this question, please email the DAS team at DAS@dwyeromega.com
Date published: 2024-10-16
How would I connect wires to this signal conditioner? Are there screw terminals on the back?
There are a series of numbered screw terminals on the back of this unit. They are identified by a table printed on the side of the case and also in the user's manual.
Date published: 2024-10-25