Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

DR-IO-IAC-R0-280P

Voltage Conversion I/O Modules: Convert TTL Levels to PLC Levels and PLC Levels to TTL Levels

C$57.36

Article# DR-IO-IAC-R0-280P

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-9 C$57.36
10-24 C$54.49
25-49 C$53.34
50-99 C$51.05
100-199 C$49.90
200+ C$48.76

Only 665 left

Quantité limitée

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Approvals CE, CSA, UL
Height 60 mm
Input Type Digital
Isolation 4000 Vrms
Length 80 mm
Logic Positive
Mounting DIN Rail 35 mm Standard “C” or as Top Hat
Number of Inputs 1
Operating Temperature, Max 70 °C
Operating Temperature, Min -30 °C
Storage Temperature, Max 100 °C
Storage Temperature, Min -40 °C
Voltage Measurement Range 90 to 280 Vac
Width 7.5 mm
Voir toutes Spécs Montrer moins
Voltage Conversion I/O Modules: Convert TTL Levels to PLC Levels and PLC Levels to TTL Levels DR-IO-IAC-R0-280P DR-IO-IAC-R0-280P
Rated 5 out of 5 by from Low turn on current I use these as solid state relays with the NI 9403 5V TTL DIO module. The problem I have always had is that the module only outputs 2mA per channel. These DR-IO modules let me go directly from the TTL signal to a 3A 208V powered device. If I need more than that I can used them to turn on a larger relay. The internal fuse make them a great space saver too.
Date published: 2016-02-16
Rated 5 out of 5 by from Everything looks fine Material arrived on time, good service and attention
Date published: 2023-10-05
Rated 5 out of 5 by from Quick Delivery Fast delivery and exactly what we needed. Good quality.
Date published: 2023-05-11
Rated 1 out of 5 by from output charge leak without control signal These modules leak a low level charge without no control signal applied. This is not noticeable with mechanical relays due to the low impedance which allows the charge to bleed without enabling the relay. However, with a sold state device with an high impedance will see a voltage on the input without a control signal applied.
Date published: 2020-10-29
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_4
  • loc_en_CA, sid_DR-IO-IAC-R0-280P, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 4ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration