Skip to search Skip to main content Skip to navigation

Bienvenue sur notre nouveau site Web, vous avez rencontré un problème ou un bug? Veuillez le signaler ici

Nous avons remarqué que vous veniez de . Visitez votre site local pour connaître les offres régionales et l'assistance en direct.

DRSL-RTD-LP

Choisissez une variante

Input Type

C$178.28

Article# DRSL-RTD-LP

Remises de volume disponibles
Calendrier de remise sur volume
Quantité Prix unitaire
1-4 C$178.28
5-9 C$169.37
10-24 C$165.80
25-49 C$158.67
50-99 C$155.10
100+ C$151.54

En stock

Délai de livraison (si pas en stock): 24 semaines

Spécifications du produit

<< Voir toutes les modèles de produits
Brand
Accuracy ± 0.1 %
Accuracy Note Better than 0.2°C or ±0.1% of selected range
Approvals CE, UL, RoHS
Calibration Temperature, Max 28 °C
Calibration Temperature, Min 20 °C
EMC Immunity Note NAMUR NE 21, A Criterion, Burst: <±1% of span (span = selected input range)
EMC Standard NAMUR NE 21
Electrical Output 0 to 20 mA, 4 to 20 mA
Enclosure Ratings IP20
Height 113 mm
Input Range Note Sensor Current, RTD: <150 µA;Sensor Cable Specifications: 50Ωper wire or 50 nF;Effect of Sensor Cable Resistance (3 or 4-Wire RTD): <0.002Ω/Ω;Broken Sensor Detection: >800Ω;Shorted Sensor Detection: <18Ω;
Input Type RTD
Installation Pollution degree 2 and measurement/overvoltage category II
Length 115 mm
Mounting DIN Rail 35 mm Standard, EN 60715
Noise Calibration >60 dB
Number of Inputs 1
Operating Temperature, Max 70 °C
Operating Temperature, Min -25 °C
Output Detail Range Limits (NAMUR NE43Out of Range): Below 3.8 mA or above 20.5 mA Sensor Error Detection(Dip Switch Selectable for Enableor None): Below 3.5 mA or above23 mA Incorrect DIP-Switch Setting Identification: Below 3.5 mAor above 23 mA Output Error Level: DIP switch selectable for upscale or downscale Load Resistance (Ω): ≤(Vsupply -3.3)/0.023
Output Signal Current
Output Value Process
Power Consumption 1 W, Internal - 0.65 W
Relative Humidity 0 to 95% RH (non-condensing)
Response Time < 30 ms
Response Time Note Response Time (0 to 90%, 100 to 10%): <30 ms/300 ms (selectable, provides either fast response or signal dampening as needed)
Screw Terminal Torque 0.5 Nm
Stability Load Stability: ≤0.01% of span/100 Ω
Storage Temperature, Max 85 °C
Storage Temperature, Min -40 °C
Supply Voltage 3.3 to 35 Vdc
Temperature Coefficient ≤±0.02°C/°C
Voltage Loss 3.3 Vdc
Weight 70 g
Width 6.1 mm
Wire Code Option 2 -, 3 - , 4- Wire
Wire Gauge 26 to 13 AWG
Voir toutes Spécs Montrer moins
Non Isolated Loop Powered DIN Rail RTD Input Conditioner DRSL-RTD-LP DRSL-RTD-LP
Rated 5 out of 5 by from great product simple to install, precise conversion. recomendation: add TC type T
Date published: 2016-07-25
  • y_2025, m_2, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_CA, sid_DRSL-RTD-LP, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT
fr-CA
fr
Enregistrer la configuration