Welcome to our new website, found an issue or bug? Please report it here
Back To Top
Load More Items from this family (3) ...
DIN Rail Signal Conditioners
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
Added to Your Shopping Cart

The DRG-SC Series Conditioners have models with TC, RTD, Pot, Freq., AC/DC Voltage/Current, Strain/Bridge inputs and field configurable outputs from 0-5V, 0-10V, 0-20mA.
Product Number | Input Type |
---|---|
|
RTD
|
|
Voltage, Current (bipolar)
|

The DRG-AR Series Conditioners are TC, RTC, DC or AC voltage and current input with 2 SPDT Relay Outputs. Field configurable ranges with adjustable setpoints.
Product Number | Input Type |
---|---|
|
AC Current , Voltage
|
|
RTD
|

TXDIN400 series transmitters accept thermocouple or RTD input (TX401) or process voltage, current, or resistance (TX402). Configurable via RFID with TX400-RFID accessory.

The DRSL-TEMP is an output loop powered temperature signal conditioner. Accepts Type J, Type K, or 2, 3 or 4 wire Pt100 RTD input. Slim housing, high accuracy.
Product Number | Input Type |
---|---|
|
Thermocouple, RTD
|

The DRSL-SP3 is a repeater/splitter that isolates and converts 1 bipolar process input to 2 process outputs. DIP switch selectable ranges, slim housing, high accuracy.
Product Number | Input Type |
---|---|
|
Voltage, Current
|

The DRSL-DC1-DC2 Conditioners have a DC current and voltage input and isolated and converted DC current and voltage output. DIP switch selectable range. 0.05% accuracy

The DRC-4710 and 4720 are DIN Rail bridge input signal conditioners that accept bridge (strain gage, load cell, or voltage) inputs and have 0-10Vdc or 4-20mA outputs.

TXDIN1600S strain gage/load cell transmitter accepts 0.2 to 7.5 mV/V inputs with 5V excitation. Universal current, bipolar voltage output. Remote tare, front panel config.
Product Number | Input Type |
---|---|
|
Four Wire Bridge Radiometric
|

The DRA-RTT-2 is a DIN Rail loop powered signal conditioner with RTD input and 4-20mA linearized output. It has ± 0.1% accuracy and is field rangeable and low cost.
Product Number | Input Type |
---|---|
|
RTD
|
Product Number | Input Type |
---|---|
|
Thermocouple, RTD,Thermistor, Resistance, Potentiometer, Current, Voltage
|

TXDIN1600 series has a universal thermocouple, RTD, or process input and 4-20mA output. Configuration via USB cable (sold separately). Push button user trim, relay output

The DRSL-LPI Series Conditioners are 1 or 2 channel analog input loop powered isolators. 1:1 signal ratio, low input voltage drop, slim housing.
Product Number | Number of Inputs |
---|---|
|
2
|
|
1
|

DR-IO Conditioners convert TTL levels to PLC levels and vice versa. Logic levels switch high level AC/DC circuits and vice versa. Wide logic voltage range and Low profile.
Product Number | Logic | Voltage Measurement Range |
---|---|---|
|
N/A
|
N/A
|
|
Negative
|
90 to 280 Vac
|
|
Positive
|
90 to 280 Vac
|

The DRSL-TC Series are isolated or non-isolated thermocouple input signal conditioners. Accepts Type J and Type K TC's. DIP switch selectable ranges, slim housing.
Product Number | Input Type |
---|---|
|
Thermocouple
|
|
Isolated thermocouple
|

The DRP-8500 Series Conditioners have voltage, current, RTD, TC and Str Gage inputs. 8500 series has frequency outputs. 8600 series has 24VDC logic outputs.
Product Number | Input Type |
---|---|
|
Strain Gage
|

The IDRN-IDRX Conditioners are TC, RTD, process, frequency, AC voltage input and provide analog or digital outputs. IDRN provides process out. IDRX provides RS-485 Output.
Product Number | Accuracy | Electrical Output | Input Type | Number of Inputs |
---|---|---|---|---|
|
± 0.1 %
|
4 to 20 mA
|
Frequency, Pulse
|
1
|
|
± 0.1 %
|
4 to 20 mA
|
Voltage, Current
|
2
|
|
± 0.01 %
|
N/A
|
Frequency, Pulse
|
2
|
|
± 0.1 %
|
2-Wire RS-485
|
Voltage, Current
|
2
|
|
± 0.2 %
|
N/A
|
Strain Gage, Bridge Transducer-Signal
|
2
|

The DRF-LC Series Conditioners are load cell input with 0-10V or 4-20mA output. For load cells with 1, 2, or 3 mV/V output. Full scale at 10, 20, or 30mV. Pre-tare jumpers
Product Number | Voltage Measurement Range |
---|---|
|
0 to 20 mV dc
|
|
0 to 30 mVdc
|

The DRSL-DC1-DC2 Conditioners have a DC current and voltage input and isolated and converted DC current and voltage output. DIP switch selectable range. 0.2% accuracy
Product Number | Input Type |
---|---|
|
Voltage, Current
|

The DRC-8900 Series Conditioners are available with TC, RTD, or mA inputs and Voltage outputs. Inputs and outputs are isolated and linearized. 24Vdc power w/ slim housing.

The DRSL-DISPLAY Programmer is required to program DRST-AC, DRST-DC, DRST-UN, DRST-UR, DRSL-U devices. Snaps onto the front panel with transferable configurations.
Product Number | Display Type |
---|---|
|
LCD
|
DIN Rail Signal Conditioners
DIN rail signal conditioners convert input signals from thermocouples, RTDs, and more into unif...
[+]